ELECTRIC SAUNA HEATER
1716-450-171809 1716-600-171809 1716-800-171809
314 SKSR 11-3 A
Product Manual
RING WALL STJ
REWARD YOURSELF
Page 1: ...ELECTRIC SAUNA HEATER 1716 450 171809 1716 600 171809 1716 800 171809 314 SKSR 11 3 A Product Manual RING WALL STJ REWARD YOURSELF...
Page 2: ...Preparing for sauna heater installation 7 3 2 Installation 7 3 2 1 Sauna heaters installation 8 3 2 2 Changing the handedness of the heater 10 3 3 Main connection 10 3 4 Electric heating toggle 11 3 5...
Page 3: ...ne you can preset the time after which the sauna heater will turn on For example by turning the knob at 6 the sauna heater will turn on after six hours and stay warm for three hours unless the timer i...
Page 4: ...EATER S CONTROL THERMOSTAT IS LOCATED AT THE SAME ZONE 2 3 Heating the sauna Before turning the sauna heater on make sure the sauna room is suitable for taking a sauna bath When heated for the first t...
Page 5: ...ones regularly at least once a year and replace small and broken stones with new larger stones Stones are piled so that they cover the heating elements Do not however pile a large heap of stones on th...
Page 6: ...if it is first turned further than the desired time and then turned back to the desired time If the switch has not travelled back to 0 position after finishing bathing turn it to 0 manually 2 5 2 The...
Page 7: ...paring for sauna heater installation Check the following before installing the sauna heater 1 The ratio of the heater s input kW and the sauna room s volume m3 Volume input recommendations are present...
Page 8: ...wall The lower bolts are installed and tightened at the end 2 Turn the heater upside down The installation holes 4x for the wall mounts are located in the bottom plate see the arrows 3 Install the hea...
Page 9: ...m From the front surface D mm To ceiling F mm To the floor K mm B mm J mm circa kg 4 5 6 0 8 0 4 6 5 9 8 13 1900 1900 1900 50 70 100 50 70 100 1200 1250 1250 120 120 120 170 190 220 230 230 230 37 37...
Page 10: ...i permanent connection Use H07RN F 60245 IEC 66 cables or a corresponding type Other output cables signal lamp electric heating toggle must also adhere to these recommendations Do not use PVC insulate...
Page 11: ...ric heating toggle Connectors N 55 and the heating elements are simultaneously live 230V The sauna heater thermostat also controls the heating toggle In other words home heating turns on once the saun...
Page 12: ...2 3 6 4 5 N L2 1 2 3 6 4 5 400V 415V 3N L1 L2 L3 230V 240V 1N 2 Vermogensingang Entrada de 2 Merkkilamppu Signallampa Signal lamp Kontrolleuchte Contact Sterowanie ogrzewaniem elektrycznym lampa sygna...
Page 13: ...ock OYKF 1 1 1 1 3 5408013 Thermostat OLCH 1 1 1 1 4 7812550 Mains connector NLWD 1 1 1 1 1 5 7712000 Cable clamp NKWA 1 1 1 1 6 4309555 Knob YWWA 11 2 2 2 2 7 4316222 Heating element SEPC 63 1500W 23...
Page 14: ...uipment you make an important contribution for the protection of our environment Please note that the product is returned to the recycling centre without any sauna rocks and soapstone cover Please con...