Helo 1118-60-04 Installation And User Manual Download Page 32

 

1.  Quick instructions for use of the sauna heater 

 

1.1. Check before taking a sauna bath 

 
1.  The sauna room is suitable for taking a sauna bath. 
2.  The door and the window are closed. 
3.  The sauna heater is topped with stones that comply with the manufacturer's recommendations, the heating elements are 
 

covered with stones, and the stones are piled sparsely. 

 
NOTE! Ceramic rocks are not allowed. 

A pleasant, smooth sauna bath temperature is about 70 °C degrees. 

Rearrange the sauna stones at least once a year and replace any weathered stones. This enhances air circulation between the 
stones, which extends the useful life of the heating elements. 

If you encounter any problems, please contact the manufacturer's warranty service shop.  

For additional information about enjoying a sauna bath, please visit our website at www.helosauna.com 

1.2. Operation of the sauna heater controls 

 
The main switch is located on the side of the contactor box. The sign shows the position of the switch. ( 0  I ) 
Refer to the specific control panel operating instructions. 
 

2.  Information for users 

 

Persons with reduced physical and mental capacity, sensory handicap, or little experience and knowledge about how the device 
is operated (e.g. children), should only operate the device while supervised or according to instructions given by the persons in 
charge of their safety. 

Make sure that children aren't playing with the sauna heater. 

2.1. Sauna room 

 

The walls and ceiling of a sauna room should be thermally well insulated. All surfaces that store heat, such as tiled and 
plastered surfaces must be insulated. It is recommended to use wooden panel cladding inside the sauna room. If there are heat 
storage elements in the sauna room, such as decorative stone, glass etc., note that these elements may extend the pre-heating 
period even though the sauna room is otherwise well insulated (see page 5, section 3.1. Preparing for sauna heater installation).

 

 

2.2. Recommended sauna room ventilation 

 

Please refer to the ventilation instructions on page 7. 

 

2.3. Heating the sauna 

 

Before turning the sauna heater on, make sure the sauna room is suitable for taking a sauna bath. When heated for the first 
time, the sauna heater may emit some odour. If you detect any odour while the sauna heater warms up, disconnect the sauna 
heater briefly, and air the room. Then you can turn the sauna heater on again. The heating of a sauna should be started roughly 
an hour before you plan to take a sauna bath, so that the stones have time to heat up properly and the air warms up evenly in 
the sauna room. 

Do not put any objects on the sauna heater. Do not dry clothes on the sauna heater or anywhere in its vicinity. 

 

 

 

Installation and User Manual HELO ROXX D 

 

Summary of Contents for 1118-60-04

Page 1: ...max 9 kW WE 4 1 230V 240V 1N 2 max 6 kW WE 4 3 230V 3 max 9 kW OHJAUSKESKUKSET CONTROL PANELS STEUERGER TE 1601 12 RA 12 Digi II 1601 13 RA 13 Digi I 1601 16 RA 16 Easy 1601 18 RA 18 Midi 7013470 314...

Page 2: ...LOT WE 3 400V 415V 3N max 9 kW WE 4 1 230V 240V 1N 2 max 6 kW WE 4 3 230V 3 max 9 kW OHJAUSKESKUKSET 1601 12 RA 12 Digi II 1601 13 RA 13 Digi I 1601 16 RA 16 Easy 1601 18 RA 18 Midi 314 SKLT 42 1 A As...

Page 3: ...mmityksen vuorottelu 8 3 7 Kiukaan suojaet isyydet 8 3 8 Kiukaan liitt minen s hk verkkoon 8 3 9 Liitosjohdon kytkent rasian sijoitus saunassa 9 3 10 Ovikytkin 10 3 11 Periaatekuva kun ohjauskeskuksen...

Page 4: ...lisuudestaan vastaavan henkil n neuvojen mukaan Tulee my s valvoa ett lapset eiv t leiki kiukaalla 2 1 Saunahuone Saunan seinien ja katon tulee olla hyvin l mp eristettyj Kaikki l mp varaavat pinnat k...

Page 5: ...ran vuodessa jolloin pienet ja rikkoontuneet kivet poistetaan ja uusia suurempia kivi laitetaan tilalle Kivet ladotaan siten ett vastukset peittyv t Vastusten p lle ei tule kuitenkaan latoa suurta kiv...

Page 6: ...kekoko A ja virransy tt kaapelin poikkipinta mm soveltuvat kiukaalle 5 Kiukaan ymp rill on oltava riitt v t suojaet isyydet Katso taulukko 1 sivulta 8 6 Kiukaan ohjauslaitteiden ymp rill on oltava rii...

Page 7: ...kiukaan lukituspalat A kiukaan takalevyss oleviin aukkoihin niin ett sis n menev osa k ntyy yl sp in Kiinnit sein teline B sein n niin p in ett rei t joihin lukituspalat kiinnitet n tulevat yl sp in T...

Page 8: ...tapauksessa poistoilmaventtiili sijoitetaan v hint n 1 m korkeammalle kuin sis n tuleva venttiili C ALUEELLE EI SAA ASENTAA RAITISILMAN SIS NTULOVENTTIILI JOS KIUASTA OHJAAVA TERMOSTAATTI ON MY S ALUE...

Page 9: ...ikiinte sti Liitosjohtona k ytet n H07RN F 60245 IEC 66 johtoa tai laadultaan v hint n n it vastaavaa johtoa My s muiden kiukaalta l htevien johtimien merkkilamppu s hk l mmityksen vuorottelu pit olla...

Page 10: ...kent rasian sijoitus saunassa Kuva 4 Kytkent rasian sijoituspaikka A Ilmoitettu v himm issuojaet isyys 1 Suositeltava kytkent rasian sijoituspaikka 2 T ll alueella tulisi k ytt silumiinirasiaa 3 T t a...

Page 11: ...i tai muualta kuin itse saunasta Helon kontaktorikotelo ja Digi 1 tai 2 ohjauspaneeleihin voidaan liitt Helo DSA 1601 35 RA 35 ovikytkinadapteria tuotenumero 001017 sek ovikytkin Helon tuotenumero 004...

Page 12: ...Kontaktorikotelo Kiuas Kiuas Silikon 4 x 0 25 LiYCY 10 x 0 25 Tuntoelin OLET 19 S hk sy tt 230 240V 1N 2 230V 3 400 415V 3N Ohjauskeskus Ohjauskeskus 1601 12 Ohjauskeskus kontaktorikotelo Kontaktorik...

Page 13: ...SEPC 64 SEPC 65B 2000W 3000W 1 2 3 354 SKLT 7 A 2 3 1 1 1 Sy tt N tet Stromnetz Power input 1 2 3 1 2 3 4 5 6 1 2 3 6 4 5 230 V 3 L1 L2 L3 N 1 2 3 6 4 5 230V 240V 1N 2 N L1 L2 1 2 3 6 4 5 400V 415V 3...

Page 14: ...tenumero Tuotenimitys Cava Roxx D 60 Cava Roxx D 90 1 4071002 Rosti 1 1 2 7712000 Vedonpoistin 1 1 3 7812550 Kytkent rima NLWD 1 1 1 1 4 4316221 Vastus SEPC 64 3 4 5207518 Vastus SEPC 65B 3 Asennus ja...

Page 15: ...onmental protection This product must not be disposed with normal household waste at the end of its life cycle Instead it should be delivered to a collecting place for the recycling of electrical and...

Page 16: ...BOXES WE 3 400V 415V 3N max 9 kW WE 4 1 230V 240V 1N 2 max 6 kW WE 4 3 230V 3 max 9 kW CONTROL PANELS 1601 12 RA 12 Digi II 1601 13 RA 13 Digi I 1601 16 RA 16 Easy 1601 18 RA 18 Midi 314 SKLT 43 A Ins...

Page 17: ...7 3 6 Electric heating toggle 8 3 7 Sauna heater safety clearances 8 3 8 Connection of the sauna heater to the mains 8 3 9 Locating the connecting box for the connection cable in the sauna room 9 3 10...

Page 18: ...le supervised or according to instructions given by the persons in charge of their safety Make sure that children aren t playing with the sauna heater 2 1 Sauna room The walls and ceiling of a sauna r...

Page 19: ...egularly at least once a year and replace small and broken stones with new larger stones Stones are piled so that they cover the heating elements Do not however pile a large heap of stones on the heat...

Page 20: ...power supply cable mm for the sauna heater in question 5 Conform to the specified safe clearance around the sauna heater Please refer to table 1 on page 8 6 There should be enough room around the saun...

Page 21: ...he locking wedges A through the holes in the heater so that the ingoing part is turned upwards The wall mount B is attached to the wall so that the holes where the locking wedges are secured to are up...

Page 22: ...tilation In this case the exhaust valve is installed min 1m higher than the inlet valve DO NOT ISTALL INLET VALVE WITHIN ZONE C IF THE SAUNA HEATER S CONTROL THERMOSTAT IS LOCATED IN THE SAME ZONE 3 5...

Page 23: ...3 1900 100 350 1070 38 Table 1 Safety clearances 3 8 Connection of the sauna heater to the mains The sauna heater must be connected to the mains by a qualified electrician and in compliance with curre...

Page 24: ...the connection cable in the sauna room Image 4 Location for the connection box A Specified minimum safety clearance 1 Recommended location for the connecting box 2 Silumin box recommended in this area...

Page 25: ...y using a timer must have a door switch Helo contactor box and Digi 1 and 2 can be fitted with either a Helo DSA 1601 35 RA 35 door switch adapter item number 001017 or a Helo door switch adapter item...

Page 26: ...llow 1 Blue 2 White 3 Red 4 Yellow A1 Valk Vit White Wei A2 Ruskea Brun Brown Braun A3 Vihre Gr n Green Gr n A4 Kelt Gul Yellow Gelb A5 Harm Gr Grey Grau B1 Rosa Ljusr d Pink Rosa B2 Sin Bl Blue Blau...

Page 27: ...12 kW 6 0 9 0 230 V SEPC 64 SEPC 65B 2000W 3000W 1 2 3 354 SKLT 7 A 2 3 1 1 1 2 3 1 2 3 4 5 6 1 2 3 6 4 5 230 V 3 L1 L2 L3 N 1 2 3 6 4 5 230V 240V 1N 2 N L1 L2 1 2 3 6 4 5 400V 415V 3N L1 L2 L3 Teho...

Page 28: ...name Cava Roxx 60 Cava Roxx 90 1 4071002 Rock grate 1 1 2 7712000 Strain relief 1 1 3 7812550 Mains connector NLWD 1 1 1 1 4 4316221 Heating element SEPC 64 3 4 5207518 Heating element SEPC 65B 3 Ins...

Page 29: ...ntal protection This product must not be disposed with normal household waste at the end of its life cycle Instead it should be delivered to a collecting place for the recycling of electrical and elec...

Page 30: ...BOXES WE 3 400V 415V 3N max 9 kW WE 4 1 230V 240V 1N 2 max 6 kW WE 4 3 230V 3 max 9 kW CONTROL PANELS 1601 12 RA 12 Digi II 1601 13 RA 13 Digi I 1601 16 RA 16 Easy 1601 18 RA 18 Midi 314 SKLT 43 A Ins...

Page 31: ...7 3 6 Electric heating toggle 8 3 7 Sauna heater safety clearances 8 3 8 Connection of the sauna heater to the mains 8 3 9 Locating the connecting box for the connection cable in the sauna room 9 3 10...

Page 32: ...le supervised or according to instructions given by the persons in charge of their safety Make sure that children aren t playing with the sauna heater 2 1 Sauna room The walls and ceiling of a sauna r...

Page 33: ...egularly at least once a year and replace small and broken stones with new larger stones Stones are piled so that they cover the heating elements Do not however pile a large heap of stones on the heat...

Page 34: ...power supply cable mm for the sauna heater in question 5 Conform to the specified safe clearance around the sauna heater Please refer to table 1 on page 8 6 There should be enough room around the saun...

Page 35: ...he locking wedges A through the holes in the heater so that the ingoing part is turned upwards The wall mount B is attached to the wall so that the holes where the locking wedges are secured to are up...

Page 36: ...tilation In this case the exhaust valve is installed min 1m higher than the inlet valve DO NOT ISTALL INLET VALVE WITHIN ZONE C IF THE SAUNA HEATER S CONTROL THERMOSTAT IS LOCATED IN THE SAME ZONE 3 5...

Page 37: ...3 1900 100 350 1070 38 Table 1 Safety clearances 3 8 Connection of the sauna heater to the mains The sauna heater must be connected to the mains by a qualified electrician and in compliance with curre...

Page 38: ...the connection cable in the sauna room Image 4 Location for the connection box A Specified minimum safety clearance 1 Recommended location for the connecting box 2 Silumin box recommended in this area...

Page 39: ...y using a timer must have a door switch Helo contactor box and Digi 1 and 2 can be fitted with either a Helo DSA 1601 35 RA 35 door switch adapter item number 001017 or a Helo door switch adapter item...

Page 40: ...llow 1 Blue 2 White 3 Red 4 Yellow A1 Valk Vit White Wei A2 Ruskea Brun Brown Braun A3 Vihre Gr n Green Gr n A4 Kelt Gul Yellow Gelb A5 Harm Gr Grey Grau B1 Rosa Ljusr d Pink Rosa B2 Sin Bl Blue Blau...

Page 41: ...12 kW 6 0 9 0 230 V SEPC 64 SEPC 65B 2000W 3000W 1 2 3 354 SKLT 7 A 2 3 1 1 1 2 3 1 2 3 4 5 6 1 2 3 6 4 5 230 V 3 L1 L2 L3 N 1 2 3 6 4 5 230V 240V 1N 2 N L1 L2 1 2 3 6 4 5 400V 415V 3N L1 L2 L3 Teho...

Page 42: ...name Cava Roxx 60 Cava Roxx 90 1 4071002 Rock grate 1 1 2 7712000 Strain relief 1 1 3 7812550 Mains connector NLWD 1 1 1 1 4 4316221 Heating element SEPC 64 3 4 5207518 Heating element SEPC 65B 3 Ins...

Page 43: ...ntal protection This product must not be disposed with normal household waste at the end of its life cycle Instead it should be delivered to a collecting place for the recycling of electrical and elec...