Helo 0315-44-040518 Installation And User Manual Download Page 8

 

 

 
 
 

 

3.3 

Safety distances

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Image. 2 Safety clearances 

 

 
 

 

Table 1 Safety clearances 

 

 

 

 
 

 
 
 
 
 
 
 

Power 

Saunaroom 

Safety clearances min. 

Adequate amount 

of stones 

kW 

Volym 

 

m

3

 

Min 

Height 

 

mm 

On the sides 

mm 

In front 

mm 

Till tak 

mm 

To the ceiling 

mm 

 
 

Approx. kg 

4,4 
6,6 
8,0 

4-6 
5-9 

8-12 

1900 
1900 
1900 

50 
50 
50 

50 
50 
50 

1135 
1135 
1135 

100 
100 
100 

20 
20 
20 

(mm) 

*) = Absolute measure 

40

*)

 

448 

min 20 

min 30 

**)

(mm)

**) = Se section 3.4

364 D

20 min 

30 min

765 F 

min 1900 

Installation and User Manual  

FONDA

 

Summary of Contents for 0315-44-040518

Page 1: ...ELECTRIC SAUNA HEATER 0315 44 040518 0315 66 040518 0315 80 040518 CONTROL PANEL 1601 27 T1 314 SKCP 1 3 C Installation and User Manual FONDA...

Page 2: ...tallation steps 7 3 3 Safety distances 8 3 4 Installation of control unit and sensor 9 3 5 Connection of the sauna heater to the mains 9 3 6 Locating the connecting box for the connection cable in the...

Page 3: ...ntal capacity sensory handicap or little experience and knowledge about how the device is operated e g children should only operate the device while supervised or according to instruc tions given by t...

Page 4: ...R S CONTROL THERMOSTAT IS LO CATED IN THE SAME ZONE 2 3 Heating the sauna Before turning the sauna heater on make sure the sauna room is suitable for taking a sauna bath When heated for the first time...

Page 5: ...ating elements For a sufficient amount of stones refer to Table 1 on page 8 Any small stones in the package of stones must not be piled on the sauna heater The warranty does not cover defects resultin...

Page 6: ...the sauna heater for maintenance purposes Also a doorway can be considered as a maintenance area 3 1 Installation Note The installation template is printed on the lid of the sauna heater box Follow th...

Page 7: ...o them 2 Then install the sauna heater so that the upper supporting iron is touching the groove in the wall mount and move the heater backwards as far as it goes towards the wall It might be necessary...

Page 8: ...s kW Volym m3 Min Height mm On the sides A mm In front D mm Till tak F mm To the ceiling K mm Approx kg 4 4 6 6 8 0 4 6 5 9 8 12 1900 1900 1900 50 50 50 50 50 50 1135 1135 1135 100 100 100 20 20 20 mm...

Page 9: ...Other output cables signal lamp electric heating toggle must also adhere to these recommendations Do not use PVC insulated cable as a connection cable for the sauna heater A multipolar e g 7 pole cabl...

Page 10: ...commended in this area 3 This area should be avoided Always use a silumin box In other areas use a heat resisting box T 125 C and heat resisting cables T 170 C The connection box must be clear of obst...

Page 11: ...2 White 3 Red 4 Yellow Limiter Connector strip Sensor cable Heater Control panel T1 Sensor OLET 28 Sauna heater Silicone 4 x 0 25 Control panel T1 LiYCY 8 x 0 25 Input 230V 240V 1N 2 230V 3 400V 415V...

Page 12: ...tukset V rmeelement Tennid Heating elements Heizeelement Resistores T rmicos l ments chauffants Elementy grzewcze 1 Sy tt N tet Stromnetz Power input Puissance absorb e Vermogensingang Entrada de alim...

Page 13: ...nmental protection This product must not be disposed with normal household waste at the end of its life cycle Instead it should be delivered to a collecting place for the recycling of electrical and e...

Reviews: