Intended use

 

ƒ

The sliding door fittings are only suitable for dry indoor spaces.

 

ƒ

Open and close hand-operated sliding elements using only 

the intended door handles and flush pulls.

 

ƒ

Do not slam and shove hand-operated sliding elements; slow-

ly guide them into the desired position.

 

ƒ

Any other use is considered improper and will invalidate all 

liability and warranty.

Safety instructions

 

ƒ

Installation and commissioning may only be carried out by 

qualified personnel.

 

ƒ

Suitable protective clothing must be worn during installation.

 

ƒ

We recommend the installation to be carried out by two peo-

ple.

 

ƒ

There is a risk of injury due to moving parts in the sliding area 

of the door leaf.

Requirements for the wall, ceiling and floor and the fixing ma

-

terial

 

ƒ

The load bearing capacity of the wall or ceiling must meet sta-

tic and dynamic requirements.

 

ƒ

The substructure must be permanently capable of bearing 

loads, flat and plumb (max. tolerance 2 mm per metre).

 

ƒ

The fixing material must be suitable for the substructure and 

meet the static and dynamic requirements. Refer to the tech-

nical instructions for the fixing material. 

 

ƒ

The fixing material is not included in the scope of delivery.

Maintenance

The hardware parts are almost maintenance-free and easy to 

clean. The sliding door fittings must be checked regularly for signs 

of wear or damage. Damaged systems may not be operated any 

longer. Furthermore, all fastening elements such as screws, nuts, 

etc. must be checked and a functional test must be carried out. Re-

pair work must be carried out by qualified personnel or specialist 

companies. Only original spare parts are to be used.

Cleaning

Do not clean anodized aluminum with acids or other alkaline clea-

ners. Furthermore, scouring powder and steel wool should not be 

used for cleaning. Dust, stains and light soiling can be removed 

with lukewarm water. Persistent soiling such as gypsum or cement 

remnants can be easily removed if you add a few squirts of a con-

ventional wetting agent (like dish washing liquid) to the water. A 

small squirt of a wetting agent is sufficient to obtain good results 

during cleaning. We explicitly point out that the anodized coating 

can be damaged by mortar and lime water. That means it is im-

portant that the bucket with water does not contain any substances 

other than a wetting agent.

Disposal

Disassembly of the system is carried out in the reverse order of in-

stallation and must be performed by qualified personnel. The pro

-

duct must be disposed of in an environmentally friendly manner. 

Refer to the national statutory regulations.

3

For safe and proper use, follow these instructions. 

Keep them for future reference.

Technical information / Safety instructions

Clean the tread of track

Important advice to prevent injury to persons and 

damage to property

About these instructions     

 

These instructions describe the installation of the sliding door sys-

tem  HELM  Modular.Concept  80  glass  -  wall  installation  with  18 

mm spacer profile and pelmet. The installation is shown using the 

example of a right-opening door. For left-opening doors, the instal-

lation must be carried out in mirror image.

Use glass leaves

 

ƒ

Glass panels with self-cleaning coating cannot be used with 

our fittings.

 

ƒ

Glass  doors  and  glass  elements  that  exhibit  damages  (e.g. 

edge damage, shell-shaped bursts, chips or scratches) must 

not be installed.

 

ƒ

Ensure the correct selection of the fittings.

 

ƒ

Set the gap dimension so that contact with hard materials is 

prevented on all sides.

 

ƒ

Check the necessity of an edge protection for edges above 

the floor or on longitudinal edges.

Clean the glass panel in the clamping areas as well 

as the glass clamps e. g. with special UV cleaner or 

acetone until they are free of grease.

When using LSG:

fill all filling holes (front and back side) with two-com

-

ponent adhesive.

Note: Please follow the instructions in the manual of 

the two-component adhesive.

 

ƒ

certified according to DIN EN 1527:2013 (200.000 cycles)

 

ƒ

max. leaf weight: 80 kg

 

ƒ

suitable for tempered safety glass (TSG) and laminated safety 

glass (LSG consisting of two TSG panels)

 

ƒ

leaf thickness: TSG 8/10 mm, LSG 8,76/10,76 mm

 

ƒ

the ratio of door height to door width must not exceed 2,5:1

 

ƒ

all dimensions in millimeter

Summary of Contents for MK-L 80 G 148

Page 1: ... Installation instructions HELM MK L 80 G 148 Schiebetürsystem für Flügel bis 80 kg Wandmontage mit 18 mm Abstandsprofil und Verblendung Sliding door system for leaves up to 80 kg wall installation with 18 mm spacer profile and pelmet DE EN ...

Page 2: ...it lauwarmem Wasser entfernen Hartnäckige Schmutz stellen wie Gips oder Zementreste lösen sich leicht wenn Sie einige Spritzer eines herkömmlichen Netzmittels z B Geschirr spülmittel ins Wasser geben Ein kleiner Spritzer vom Netzmittel reicht aus um gute Ergebnisse bei der Reinigung zu erzielen Wir weisen ausdrücklich darauf hin dass die Eloxalschicht mit Mörtel oder Kalkwasser beschädigt werden k...

Page 3: ...shing liquid to the water A small squirt of a wetting agent is sufficient to obtain good results during cleaning We explicitly point out that the anodized coating can be damaged by mortar and lime water That means it is im portant that the bucket with water does not contain any substances other than a wetting agent Disposal Disassembly of the system is carried out in the reverse order of in stalla...

Page 4: ...HELM 4 Flügelhöhe Leaf height FH BH 42 10 Legende Legend FH Flügelhöhe leaf height BH Bohrhöhe drill height Einbauschnitt Berechnungen Drawing Calculations ...

Page 5: ...min A A 650 mm A B 650 mm B B 860 mm Laufschienenlänge Track length LL FB x 2 1 x Ü 2 x 5 Lichte Weite Clear width LW LL 2 x 5 FB 1 x Ü Legende Legend LL Laufschienenlänge track length LW Lichte Weite clear width Ü Überlappung overlapping FB Flügelbreite leaf width A B A B ...

Page 6: ...HELM 6 Benötigtes Werkzeug Required tools Lieferumfang Scope of delivery A B ...

Page 7: ...HELM 7 Montageschritte Installation steps 1 3 A 2 ...

Page 8: ...HELM 8 3 B Montageschritte Installation steps 2 x 2 x 4 ...

Page 9: ...HELM 9 5 Montageschritte Installation steps 6 7 ESG VSG ...

Page 10: ...HELM 10 Montageschritte Installation steps 9 A VSG 9 B 8 ...

Page 11: ...HELM 11 10 11 A 11 B 2 x 2 x Montageschritte Installation steps 12 13 ...

Page 12: ...vement We appreciate your understanding that we assume no liability for any typing errors or any other errors Thereproductionofthisdocument in extracts or complete is not permitted without our express written permission Hiermit werden alle früheren Montage anleitungen ungültig Die technischen Angaben entsprechen dem neusten Stand Änderungen in Konstruktion und Formgestaltung die dem Fortschritt di...

Reviews: