15
HM1734-WM STRAIN GAGE INPUT MODULE
Data Map for HM1734-WM on Ethernet/IP
OUTPUT BITS
Local:2:O.Data[0].0
1
cal mode
Local:2:O.Data[0].1
0
run mode
Local:2:O.Data[0].2
0
ch1 clear tare
Local:2:O.Data[0].3
0
ch1 tare
Local:2:O.Data[0].4
0
ch1 set adtrim
Local:2:O.Data[0].5
0
read adtrim
Local:2:O.Data[0].6
0
ch2 clear tare
Local:2:O.Data[0].7
0
ch2 tare
Local:2:O.Data[1]
Local:2:O.Data[1].0
0
ch2 set adtrim
Local:2:O.Data[1].1
0
ch1 only
Local:2:O.Data[1].2
0
4msec
Local:2:O.Data[1].3
0
8msec
Local:2:O.Data[1].4
0
16msec
Local:2:O.Data[1].5
0
32msec
Local:2:O.Data[1].6
0
40msec
Local:2:O.Data[1].7
0
48msec
Local:2:O.Data[2]
5
Local:2:O.Data[2].0
1
rev418 enable
Local:2:O.Data[2].1
0
10x scale
Local:2:O.Data[2].2
0
samples = 10
Local:2:O.Data[2].3
0
samples = 20
Local:2:O.Data[2].4
0
samples = 50
Local:2:O.Data[2].5
0
zero band .025
Local:2:O.Data[2].6
0
zero band .050
Local:2:O.Data[2].7
0
zero band .075
Local:2:O.Data[3]
Local:2:O.Data[3].0
0
read scale sets
Local:2:O.Data[3].1
0
auto cal mode
Local:2:O.Data[3].2
0
ch1 auto tune
Local:2:O.Data[3].3
0
ch2 auto tune
Local:2:O.Data[3].4
0
read autocal values
Local:2:O.Data[3].5
0
read sample set
Local:2:O.Data[3].6
0
read mv_v sets
Local:2:O.Data[3].7
0
extra test