6.PREPARATION FOR MEASUREMENT
Check the following for damages and status
1. Display.
Do not use the Instrument if the display looks
abnormal.
2. Keypad.
Visually check the Keypad.
A damaged keypad will cause the instrument to
malfunction.
3. Test Leads.
Verify test Leads are free of cracks and check
continuity.
Faulty Test Leads will cause inaccurate readings.
4. Batteries.
The instrument will operates optimally with alkaline
batteries.
5.TIN5D - INSTRUMENT LAYOUT
Test Leads connections
Liquid crystal
display
Voltage
Selection
Keys
Reset (if depressed for less than one second)
switches "off" the instrument when depressed
for more than five seconds.
Clear a fault.
Start and Stop the test.
Go to Main Menu.
Switches "ON"
the Instrument
GUARD
SAFETY PRECAUTION!
—
Use only on de-energised system.
—
Check test leads for defects.
—
Always earth circuit under test.
—
After testing, allow a few seconds for instrument to
discharge circuit under test .
OPERATING INSTRUCTIONS
1.Depress "ON" .
2.Insert leads into the instrument observing colour coding.
3.Clip BLACK Lead to earth .
4.Select test voltage and follow display instructions.
CAUTION
5.Touch RED lead to conductor under test . Stop test
Immediately if warning message and/or buzzer sound. This
indicates the presence of an external voltage which must be
removed.
Before proceeding, clear the fault by depressing "Test".
6.Connect RED lead to conductor and Depress "Test"(tests up
to 99.9S)
7.Display shows test duration, real time bargraph voltage
indication and insulation resistance.
EARTH
+HV
HIGH VOLTAGE
DIGITAL INSULATION TESTER
MICROPROCESSOR CONTROLLED
10kV
1KV
2.5kV
ON
OFF
COVERING
OUTER
SHEATING
EARTH
INSULATION
GUARD
CABLE CORE
LINE
TEST
START / STOP
-HV
MODEL
TIN5D
LINE
0V
5kV
Summary of Contents for Top Tronic TIN4D
Page 16: ......