HELLER HECS11 Instruction Manual Download Page 7

5.

 

Disconnect the electric motor connection and remove the complete filter assembly by pulling out 
from the top and then lifting the filter assembly - up and out. 

6.

 

The air filter is connected into the back cover via two clips at the top. Release by pressing the two 
clips down and give it a little push. Care full not to damage the filter. 

CAUTION:  Do not immerse or allow the motor or electric cables to come in contact with any liquid. 

i.

 

Do not immerse the Photo catalysis filter in water or any other liquid. This filter should not be 
allowed to become wet. It should be placed in a sunny position to reactivate it. 

7.

 

The water curtain is supported by two rollers, which can be removed for cleaning with mild soap. It 
is recommended to be cleaned once every 6 months 

8.

 

Wipe out and dry the water reservoir. Replace the water drainage plug. It is recommended to be 
cleaned once every 1-2 months 

9.

 

Dry the filter and filter assembly and the water curtain before re-assembling. 

10.

 

To clean the exterior surfaces simply wipe over with a soft damp cloth. Should it be necessary, 
greasy marks may be removed from the surfaces by using mild soap and a cloth dampened in hot 
water. Avoid all other types of detergents, cleaners, solvents that may contain chemicals which 
could damage parts of the unit. Thoroughly dry all parts before storage. 

11.

 

Store in a cool dust free location for next use. 

 
Troubleshooting 
 

Always check full product operation as detailed above before returning any product as faulty. 

On humid days the unit may not appear to be cooling correctly. This is due to the air already being saturated 
with water. Adding more water to the air will not result in reducing the air temperature. In these conditions, 
it is advisable to operate the unit as a fan to circulate room temperature air. 

Specifications  

Rated voltage frequency 

220-240VAC    50Hz 

Input power 

70W 

Max. Air Volume 

>20m³/min 

Water Tank Capacity 

10 Litres 

Modes / Functions 

New Weight 

6kg 

Dimensions 

300 x 397 x 650mm 

 

Australian Customer Service 

GAF Control (Sales) Pty Ltd  
P.O Box 19  
Altona North Victoria 3025  
Phone: 1300 659 489  
Hours: 9am-5pm (EST) Mon-Fri  
www.gafcontrol.com.au  
*This product may vary slightly to the product illustrated due to ongoing product development. 

 

Summary of Contents for HECS11

Page 1: ...Instruction Manual 10L Evaporative Cooler Model HECS11 READ AND SAVE THESE INSTRUCTIONS ...

Page 2: ...n repair or replacement Before unplugging the power cord be sure to turn the power off When touching the unit be sure your hands are dry to prevent electrical shock Never install the unit where it is exposed to direct sunlight excessive moisture rain dust and lack of ventilation near any heat sources Avoid making contact with moving parts Never insert fingers pencils or any other objects through t...

Page 3: ...lectrical appliances It is advisable that a safety switch with a rated residual operating current not exceeding 30mA be installed in the electrical circuit supplying the appliance See your electrician for professional advice Product Introduction Features Evaporative air cooling is a natural way of cooling similar to a breeze flowing across the water which drops the temperature at the beach and has...

Page 4: ...ructions A ON OFF Press the button once to start air cooler Press again to Power OFF the air cooler When cooler is plugged into the main socket the LED will light up indicating the air cooler has power and is ready to be switched ON or OFF B SWING Press once the indicating LED will light up louver of the air cooler begins to swing horizontally and blow cool air Push the button again the LED is now...

Page 5: ...ater drainage outlet of the unit is tight Pour clean cold water into the water filler area observing the water level indicator in the bottom front panel CAUTION DO NOT SPILL OR ALLOW WATER TO COME IN CONTACT WITH THE CONTROL PANEL Do not overfill past the MAX water line Do not pour water into the ice tank Do not allow the combined use of water and ice to overfill the water reservoir When moving th...

Page 6: ...of the setting as long as there is power to the cooler step 2 when it is switched OFF and without unplugging the power plug The cooler will only remember settings when main power which the cooler is plugged into remains switched on Care Cleaning To ensure effective humidifying and filtering it is recommended that the filtering system be cleaned once every 1 2 months 1 Disconnect the unit from the ...

Page 7: ...ipe over with a soft damp cloth Should it be necessary greasy marks may be removed from the surfaces by using mild soap and a cloth dampened in hot water Avoid all other types of detergents cleaners solvents that may contain chemicals which could damage parts of the unit Thoroughly dry all parts before storage 11 Store in a cool dust free location for next use Troubleshooting Always check full pro...