Below are the colour/value that can be displayed: 
 

Ring Colour 

Particulate Matter Value (Range) 

Air Quality Status 

Green 

0-100 

Good  

Yellow 

101-200 

Average 

Red 

201+ 

Poor 

 
 

Filter Replacement Indicator: The Replace HEPA light on the display will illuminate and 
flash indicating that it is time to replace your filter. Replace the filter according to 
directions (refer to CARE, CLEANING & MAINTENANCE 

 FILTER REPLACEMENT) then 

press and hold TIMER button on your purifier for 5 seconds to reset the system. 

 
 
UV Bulb Replacement Indicator: 

The ‘UV’ light on the display will flash when it is time to 

replace the UV bulb. Replace the bulb according to direction. (Refer to CARE, CLEANING & 
MAINTENANCE 

 INSTALLING AND REMOVING UV-C BULB). To reset the UV-C Replacement 

indicator, press and hold the UV button to reset system. Hold for 5 seconds and change reset to start. 
** Control Panel Beep/ Sound: The sound emitted from pressing the buttons on the control panel can be 
turned off/on by holding the SPEED button for 5 seconds.  
 
 
 

 

CARE, CLEANING & MAINTENANCE 

 

 

 

Your appliance must be switched OFF via the main power supply and unplugged before proceeding 
with any cleaning.  

 

To clean the exterior surfaces simply wipe over with a clean, dry soft cloth. Avoid all other types of 
detergents, cleaners, solvents that may contain chemicals, which could damage parts of the unit. 

 

Never use flammable or abrasive cleaning agents such as benzene or spirits to clean the appliance.  

 

Clean the filter monthly with the brush or nozzle of your vacuum cleaner. 

 

 Never immerse the appliance in water. 

 

Never spray the appliance with liquids or submerge it in water or any other liquid. 

 

Do not stick any foreign objects or your fingers inside the unit. 

 
 
 
To Remove & Clean (or Replace) Filter: 

 
The Replace HEPA light will flash continuously indicating that it is time to replace your 
filter. Replace the filter according to directions then restart the system. Depending on 
usage, filter will last approximately 12 months (however this can vary depending on the 
air quality). 

 
 
 
 

NOTE: If the power cord set of this appliance becomes damaged, discontinue use. Repairs should be 
undertaken only by a qualified technician. 

Summary of Contents for HAP120

Page 1: ...Instruction Manual Digital Air Purifier Model HAP120 READ AND SAVE THESE INSTRUCTIONS ...

Page 2: ...rate any product with a damaged cord or plug or after the product malfunctions or is dropped or appears damaged in any way Return the complete product to the place of purchase for inspection repair or replacement Before unplugging the power cord be sure to turn the power off When touching the unit be sure your hands are dry to prevent electrical shock Fully remove the power cord from the power cor...

Page 3: ... main switch to OFF then remove the plug from the outlet This unit has hot electrical parts inside DO NOT use it in areas where gasoline paint or flammable liquids are used or stored This product must always be used and stored in the upright position The use of attachments or accessories not recommended or sold by the product distributor may cause personal or property hazards or injuries and could...

Page 4: ...then press the UV HEPA Reset Button and hold for 5 seconds to restart the system The light should remain a constant blue Please see below UV C Bulb Replacement to replace the UV bulb SAVE THESE INSTRUCTIONS BEFORE FIRST USE Before use remove all packaging and inspect the appliance for any damage If there appears to be any damage please take the unit back to place of purchase for a replacement FEAT...

Page 5: ...matically adjust the speed of the purifier to optimize room air quality when set in auto mode AIR CLEANING LAYERS ASSEMBLY 1 Select a firm level and flat location for the air purifier For proper air flow locate the unit at least 300m from any wall or furniture Make sure none of the grills are blocked 2 Carefully remove your air purifier from box and bag IMPORTANT When moving the air purifier alway...

Page 6: ... you prefer to run the purifier for a specific number of hours you can select between 1 8 hours on the display Air quality monitor detects the amount of particulate matter PM in the air The circular light on the front panel of the purifier is the air quality indicator It will change colours indicating the air quality level in the room The particulate matter value will be displayed on the circle se...

Page 7: ... SPEED button for 5 seconds CARE CLEANING MAINTENANCE Your appliance must be switched OFF via the main power supply and unplugged before proceeding with any cleaning To clean the exterior surfaces simply wipe over with a clean dry soft cloth Avoid all other types of detergents cleaners solvents that may contain chemicals which could damage parts of the unit Never use flammable or abrasive cleaning...

Page 8: ......

Page 9: ...e HEPA filter peel back the carbon layer to expose the pleated HEPA Filter If the HEPA Filter is no longer white and is covered in grey dust dirt it should be replaced IMPORTANT Do not try to wash and re use the Combination Filter Installing Removing the UV C Bulb UV Bulb Replacement Indicator the UV light on the display will flash when it is time to replace the UV bulb WARNING UV radiation is dan...

Page 10: ...ly in place Check that the Rear Cover is latched firmly in place No air circulating from unit Unplug unit Check Pre filter Charcoal HEPA filters Clean Pre filter Charcoal if necessary Replace HEPA filter if necessary Increase in noise level Make sure the filters are clean Replace if necessary An unpleasant odour is emitted from the unit Make sure the filters are clean Replace if necessary SPECIFIC...

Page 11: ...CE GAF Control Sales Pty Ltd P O Box 19 Altona North Victoria 3025 Phone 1300 659 489 Hours 9am 5pm EST Mon Fri www gafcontrol com au This product may vary slightly to the product illustrated due to ongoing product development ...

Reviews: