background image

1)  The control valve and second tank adapter are solid brass 

assuring you durability and long life.

2)  Two self cleaning teflon coated pistons control the regenera-

tion and alternating from unit to unit with conditioned water.  

They are hydraulically balanced to equalize pressure on both 

sides of the piston, allowing it to shift smoothly and quietly 

regardless of water pressure.  Large plastic spacers and 

rubber seals protect the pistons from sediment in water and 

improve service flow rates.

3)  The 1.5” meter allows for capacities from 625 to 53,125 

gallons between regenerations and will measure flow rates 

accurately between 1.5 and 75 gpm.  The 1.5” low flow meter 

allows for capacities from 310 to 26,350 gallons between re-

generations and will measure flow rates accurately between 

0.7 and 40 gpm.

4)  The NF-SERIES timer doesn’t require a time of day setting 

since it adjusts automatically to meet your needs.  Regenera-

tion can take place as often as every 90 minutes if needed.

5)  The NF-SERIES has an adjustable cycle programmer.  This 

allows you to efficiently monitor all regeneration cycles in-

cluding backwash, brine and slow rinse, rapid rinse and brine 

tank refill.

6)  In addition to regenerating with soft water, the NF-SERIES 

uses electricity only during regeneration, therefore power 

outages do not affect metering.  A convenient cycle position 

readout dial indicates which unit is in service and the status 

of the other unit.  It has no complicated interlock wiring and 

costs less to install. 

A)  Fiberglass and polyglass mineral tanks provide rust and cor-

rosion free service for years.  National Sanitation Foundation 

approved.

B)   1.5” high flow hub & lateral distribution system for minimal 

pressure loss.  

C)   Hi-Capacity Cation resin has uniform and stable resin beads 

assuring long life and maximum soft water.

D)   Gravel underbedding assures full usage of mineral beds and 

allows for a smooth and constant water flow for service and 

regeneration.

E)   Safety brine valve acts as a secondary shut-off in case of a 

power failure during regeneration.

F)   High density polyethylene brine tank has exceptional envi-

ronmental stress crack properties, eliminating cracking and 

minimizing bulging.

G)   Polypropylene salt grid allows insoluble materials to settle out.

 

 

 

 

CAPACITY  

 

SERVICE  

FLOW RATE   BACKWASH   MINERAL  

BRINE  

SALT         SHIPPING   INLET/OUTLET

  MODEL 

RESIN  

LOW SALT 

MED. SALT  

HIGH SALT  

FLOW RATE  

PEAK  

RATE  

TANKS  

TANK SIZE   STORAGE  

WEIGHT  

HEIGHT

  NAME  

CU. FT.  

GRAINS/LBS 

 GRAINS/LBS 

GRAINS/LBS 

 CONT. 15 PSI 

25 PSI 

GPM 

(INCHES) 

(INCHES) 

(POUNDS)  (POUNDS) 

(INCHES)

NF-60 

2.0 

38,000/12 

56,000/20 

64,000/30 

23.0 

32.0 

3.5 

13 x 54  18 x 40 

375 

404 

57.5

NF-90 

3.0 

57,000/18 

84,000/30 

96,000/45 

22.0 

30.0 

4.0 

14 x 65  18 x 40 

375 

539 

68.5

NF-120 

4.0 

76,000/24 

112,000/40 

128,000/60 

25.0 

34.0 

5.0 

16 x 65  24 x 41 

525 

677 

68.5

NF-150-18 

5.0 

95,000/30 

140,000/50 

160,000/75 

27.0 

37.0 

7.0 

18 x 65  24 x 50 

510 

832 

70.5

NF-150-21 

5.0 

95,000/30 

140,000/50 

160,000/75 

31.0 

41.0 

9.0 

21 x 62  24 x 50 

510 

946 

70.5

NF-180-18 

6.0 

114,000/36 

168,000/60 

192,000/90 

26.0 

35.0 

7.0 

18 x 65  24 x 50 

510 

938 

70.5

NF-180-21 

6.0 

114,000/36 

168,000/60 

192,000/90 

30.0 

40.0 

9.0 

21 x 62  24 x 50 

510 

1052 

70.5

NF-210 

7.0  133,000/42 

196,000/70 

224,000/105 

29.0 

39.0 

9.0 

21 x 62  24 x 50 

510 

1158 

70.5

NF-240 

8.0  152,000/48 

224,000/80 

256,000/120 

32.0 

42.0 

12.0  24 x 72  24 x 50 

340 

1332 

78.0

NF-270 

9.0  171,000/54 

252,000/90 

288,000/135 

31.0 

41.0 

12.0  24 x 72  24 x 50 

340 

1438 

78.0

NF-300 

10.0  190,000/60 

280,000/100  320,000/150 

30.0 

40.0 

12.0  24 x 72  24 x 50 

340 

1544 

78.0

• Cubic feet of mineral and capacities as seen above are per mineral tank. 

• Product improvements and design changes subject to change without notice.

• Service flow ratings are with the 1.5” meter. 

• Water Pressure 30 - 100 psi.

• Limit of 2 ppm of ferrous iron.  Add 3 grains of hardness per ppm of iron when sizing. 

• Water temperature is not to exceed 110ºF and cannot be subject to freezing 

• See owners manual for specific operating details 

  conditions.

• These conditioners will not purify or make your water safe to drink. 

• 

Refer to Hellenbrand Bulletin 2050 “Flow Rates and Soft Water Quality (Hardness    

• Inlet/outlet heights are approximate only.

 

  Leakage) if your application requires that levels of hardness leakage do not exceed “x”.

Manufactured by:

HELLENBRAND, INC.

(800) 626-1417

www.hellenbrand.com

106610

1/05-500

1/21/09-LBRY

DEALER NAME:

Meter Information:

Meter Accuracy Range  1-1/2” (Standard)  1.5 - 75 gpm ± 5%

 

1-1/2” (Low Flow)  0.7- 40 gpm ± 5%

Meter Capacity Range  1-1/2” (Standard)  Standard: 625-10,625 gals.

 

 

Extended: 3,125 - 53,125 gals.

 

1-1/2” (Low Flow)  Standard: 310 - 5,270 gals.

 

 

Extended: 1,550 - 26,350 gals.

NF-SERIES Specifications

A

B

C

D

G

F

E

Reviews: