![Helios Outland Firebowl FMPPC2B-875 Owner'S Manual Download Page 11](http://html1.mh-extra.com/html/helios/outland-firebowl-fmppc2b-875/outland-firebowl-fmppc2b-875_owners-manual_2120733011.webp)
En-10
1-888-514-1663 |
WWW.OUTLANDLIVING.COM
REMOVING INSECT NESTS
Clean the burner tubes often and especially if the appliance has
been sitting unused for a period of time. You must remove the gas
valve to gain access to the burner tube for cleaning.
BURNER TUBE CLEANING INSTRUCTIONS:
STEP 1
Ensure the appliance valve(s) are OFF and the cylinder valve is
closed.
STEP 2
Disconnect LP Cylinder.
STEP 3
Locate and remove the gas valve body assembly mounting
screws.
WARNING:
Small critters like
spiders and earwigs
can quickly build nests
inside the burner tube
which can obstruct
gas flow and impact
the flame height and
heat performance of
your appliance. More
seriously, a nest or
blockage of the burner
tube can cause a back
flame event, damage
to your appliance, or even extreme operator injuries!
Mounting Screws
and Nuts
STEP 4
Remove the gas valve body assembly.
STEP 5
Use a flashlight to look inside the burner tube. Use a long flexible
pipe cleaner, or long small utensil to clean out any debris or nest
material. An air tool to blow out the burner is helpful, but please
wear eye protection.
STEP 6
When the burner tube is determined to be clear, reinstall the gas
valve body assembly.
IMPORTANT: Align gas valve orifice inside burner tube.
Burner
Tube
Gas Valve
Orifice
WARNING:
The gas valve orifice should be inside the burner tube and
visible through the bug screen mesh. If your orifice and burner
tube does not line up like in the image above, please call
customer service at (888) 514-1663 or E-Mail to
[email protected].