Helios E-Stop Series User Manual Download Page 6

 

WES 2000 

– Installation and Hardware Guide 

 

 

4  

 

V 1.2 

 

Pressing the stop button on the handset will open the relay contact, the “Alarm” led will come 
on and the “Enable” led will turn off.  

 

Reset the system 

If the system has been set into alarm mode by either the button or the transmitter the red “Alarm” light 
will be on and the system will look the same as when it was first powered on.  
 

1.

 

If the system alarm was initiated via the E-stop switch, twisting the Estop button clockwise will 
disengage the E-Stop. 

2.

 

If the system alarm was initiated via handheld, reset or disable the handheld that is transmitting 
the alarm and then wait 10 seconds before resetting. For safety reasons when the system is set 
into alarm mode via a transmitter the system has a time out period before you may enable the 
equipment again.  

3.

 

After waiting 10 seconds press the reset switch until the enable light comes on and the alarm 
light goes out. (The relay contacts will close). If the enable light shows green but turns off 
immediately after releasing the equipment is still in alarm mode.  

a.

 

If the wireless transmitter was used wait another 10 seconds before attempting to reset 
the system 

b.

 

If there is a handset still currently in alarm, or the E-Stop button is still depressed the 
W.E.S. will not enable as long as there is a valid alarm state.  

 

3.2

 

Testing 

It is recommended the W.E.S. System be tested before every use to ensure you are using the correct 
handset and the system is functioning properly.  
To conduct a full test, enable the W.E.S. System and ensure the green “Enable” light turns on and then 
trigger a stop using the wireless handset. Ensure the W.E.S. triggers into alarm mode right away and 
your equipment is disconnected. If the handheld does not trigger the alarm commence troubleshooting 
as follows. 

4

 

Troubleshooting 

Problem 

Check/Solution 

Relay contacts will not close 

Check on board fuse, replace as necessary 

Reset button does not enable unit 

Ensure stop button is not engaged 
Check that all transmitters are not in alarm mode 

Handset does not trigger alarm when activated 

Ensure handset is on and is the correct unit for 
your W.E.S System 

5

 

Specifications 

5.1

 

W.E.S. Base station 

Unit Certifications 

QPS Field Certification 

UL certified for US applications.  
UL 508 & CSA 22.2 #14 

Reviews: