Page 23
Public pool basic plumbing
The additional booster pump should be
installed after the filter, using a “T” joint on the main filtration pipe.
The automatic control commands both the booster pump and the 2 way valve after it. (The 2 way valve is
installed in order to prevent undesired low water flow through the collectors caused by the main filtration
pump).
Public pool basic plumbing 2
When there is a need for total separation between the solar piping and the filtration piping it is advisable to
pump the water to the collectors by an independent pump that takes the water directly from the pool and
returns the heated water directly to the pool.
Page 23