Installation instructions Art. No. 42198, 42199

Page 2 of 2

Status 02.2016

Installation:

Make sure that the connection values for the power supply to the movement detector agree
with the data on the rating plate for this product.

This product may only be installed by a qualified specialist electrician.

Make sure before connecting to a consumer point that the maximum load of the movement
detector is not exceeded.

The connection lines to the building must be switched free from voltage and protected against
being switch on again before the installation is done. Take the appropriate automatic circuit
breakers out of the junction box in the building.

The movement detector is equipped with 2 setting options (read the Technical Data). The
switch is located on the lower side.

Turn the time setting completely to the left (shortest time period) and turn the brightness
switch completely to the right (max brightness) before doing the connection work.

Open the back cover of the device for connection. Wire up the connection lines now to the
building installation to the screw terminals of the movement detector.

Connect the neutral conductor (blue) and the red conductor with the consumer unit first of all.
Then connect the neutral conductor and the outer conductor (brown) to the voltage supply.

You can reconnect to the power supply after completion of the installation and connection
work.

Please remember that the high sensitive device can sometimes be unintentionally activated by
sudden changes in the surroundings.

Do not install the sensor in the immediate vicinity of larger devices, such as deep freezers, air
conditioning units, sources of light, heating devices and other items.. Never set up the
movement detector on heating devices, lights, swimming pools or other reflecting surfaces.

Make sure that the base has sufficient support when you are fastening the movement
detector.

The movement detector can be put into service after connecting to the power mains.

The rating plate must not be removed.

Heitronic

®

H. Vollmer GmbH
Allmendring 29
D-75203 Königsbach-Stein

Blue (N)

brown (L)

input

red

consumer load

Summary of Contents for 42198

Page 1: ...ax 12m Erfassungsbereich 180 Installationsh he 2 4m Umgebung 10 C 40 C Ansprechhelligkeit einstellbar zwischen Dunkelheit und Tageslicht ca 2 1000 Lux Einschaltdauer ca 10 Sekunden bis max 2 Minuten e...

Page 2: ...um Anschlie en ffnen Sie die hintere Abdeckung des Ger tes Schlie en Sie nun die Anschlussleitungen der Hausinstallation an die Schraubklemmen des Bewegungsmelders an Verbinden Sie zuerst den Neutrall...

Page 3: ...ensor Infra red detector Sensor range up to a max 12m Recording range 180 Installation height 2 4m Ambient temperature 10 C 40 C Response brightness Settable between darkness and daylight approx 2 100...

Page 4: ...the back cover of the device for connection Wire up the connection lines now to the building installation to the screw terminals of the movement detector Connect the neutral conductor blue and the red...

Page 5: ...teur infrarouge Port e du capteur jusqu 12 m max Secteur de saisie 180 Hauteur d installation 2 4m Temp rature ambiante 10 C 40 C Seuil de luminosit r glable entre obscurit et lumi re du jour approx 2...

Page 6: ...e de l appareil Connectez les lignes de connexion de l installation lectrique domestique aux pinces vis du d tecteur de mouvement Connectez tout d abord le conducteur neutre bleu et le conducteur roug...

Page 7: ...dstype IP 44 Sensor infrarood detector Reikwijdte sensor tot max 12m Detectiebereik 180 Installatiehoogte 2 4m Omgeving 10 C 40 C Aanspreekhelderheid instelbaar tussen duisternis en daglicht ca 2 1000...

Page 8: ...nsluiting te beginnen Open de achterste afdekking van het apparaat om het product aan te sluiten Sluit vervolgens de aansluitleidingen van de huisinstallatie aan op de schroefklemmen van de bewegingsm...

Reviews: