HeiTel TDT C1500 Configuration Download Page 13

TDT C1500 

 

Router Configuration 

4.4.

 

Diagnosing connection problems 

Under

 

Diagnose

 

you

 

will

 

find

 

a

 

number

 

of

 

functions

 

by

 

which

 

to

 

check

 

for

 

errors.

 

For

 

a

 

GSM/GPRS/UMTS

 

connection

 

the

 

function

 

GSM Modem State

 

is

 

the

 

means

 

by

 

which

 

to

 

ensure

 

that

 

everything

 

is

 

okay

 

with

 

the

 

mobile

 

network

 

connection,

 

that

 

signal

 

strength

 

is

 

sufficient

 

and

 

that

 

registration

 

with

 

the

 

provider

 

was

 

successful.

 

 

For

 

analyses,

 

system

 

information

 

and

 

the

 

router

 

logs

 

are

 

available.

 

 

 

 

If

 

a

 

connection

 

has

 

been

 

created

 

successfully,

 

data

 

on

 

the

 

registered

 

network

 

is

 

given

 

here.

 

The

 

Signal Quality

 

bar

 

indicates

 

the

 

signal

 

strength

 

of

 

the

 

mobile

 

network.

  

 

Click

 

Refresh

 

to

 

update

 

the

 

display.

 

 

 

 

Technical Production Information 

© HeiTel Digital Video GmbH 2010

 13/18

 

Summary of Contents for TDT C1500

Page 1: ...r camdisc svr cam4mobile CamDisc HNVR http www heitel com en service upgrades firmware camdisc hnvr Download CamControl LITE Demo Version http www heitel com en service downloads CamControl LITE Download CamControl PRO Demo Version http www heitel com en service downloads CamControl PRO Contents 1 Introduction 2 2 Requirements 2 3 Router Preparation 3 3 1 Insert data card 3 3 2 Power supply 3 3 3 ...

Page 2: ...12 V DC power supply unit for HeiTel transmitters 8 30 V DC power supply for Cam4mobile CamControl LITE or CamControl PRO software of version 3 82 or higher as receiver and archive access software TDT C1500 router series 12 V DC power supply for TDT C1500 router o Nominal voltage 12 V operating voltage range 7 18 V DC o Rated current 1 2 A 3G UMTS antenna A SIM card from the mobile network operato...

Page 3: ...not PIN protected 3 2 Power supply Connect to the power supply in accordance with manufacturer instructions 3 3 Network connection The C1500 router has two network interfaces WAN and LAN For router configuration with a PC or Notebook or to connect a HeiTel video system use only the LAN network interface Technical Production Information HeiTel Digital Video GmbH 2010 3 18 ...

Page 4: ...Username tdt Password tdt To configure the router proceed as follows 4 1 Creating a connection to the router Access to the Web interface is via SSL encrypted transfer Web browsers usually protest that this certificate is not trustworthy and classify the Web interface as unsafe To gain access depending on the browser an exception must be created or loading continued despite the recommendation After...

Page 5: ...ction is configurable here For a mobile network connection the area PPP Functions is used The log files and status displays under Diagnose can be used to locate errors Configuration changes to the router are temporary following a restart or power failure default or previously stored configurations are active To create a permanent configuration after entering changes under Permanent Save the functi...

Page 6: ...ions and for the hardware GSM Modem State 4 3 2 Step by step configuration PPP Interfaces can be configured in the Networking area under the function PPP Functions A PPP Interface contains the entire configuration for connection to the provider User name and password are stored the connection type e g GRPS or UMTS selected or those actions configured that are accessed following establishment of th...

Page 7: ...y No PPP interfaces configured Click Create a new PPP interface to create a new PPP Interface Accept the default setting PPP0 and select the option UMTS GPRS Click Create to open the editing mask Adjust the parameter for the SIM card used SIM card SIM 2 Technical Production Information HeiTel Digital Video GmbH 2010 7 18 ...

Page 8: ...ou now need to enter the PPP access data for the relevant provider in the editing mask Example Vodafone Germany APN web vodafone de Username Password All other settings are to be entered as shown on the screenshot Once you have made these settings complete the procedure by pressing Save Technical Production Information HeiTel Digital Video GmbH 2010 8 18 ...

Page 9: ...ged to Yes All other entries are standard settings After you click Save the previous page listing the PPP Interfaces is displayed and ppp0 must be opened again for editing Select here the Advanced Settings button Here too close this editing mask by pressing Save Technical Production Information HeiTel Digital Video GmbH 2010 9 18 ...

Page 10: ...onnection Manager Functions is required This is responsible for dynamic connection i e connection when required or static connection i e connection as soon as the router is started Click the Connection Manager Functions symbol to access the relevant function Click on the Static Connections symbol to access the relevant function Technical Production Information HeiTel Digital Video GmbH 2010 10 18 ...

Page 11: ...e Interface the ppp0 interface created is selected by default All other settings can be accepted as they are Create the entry by clicking Create Click Return to Connection Manager to return to the overview where the connection you just created is now displayed Under Activate Connection Manager select Yes and accept the settings by clicking Apply Changes To check the PPP connection to the mobile ne...

Page 12: ... If a connection was created under Active PPP Connections the current values for Type connection type Local IP WAN IP address of the router Remote IP provider IP address State status and Uptime operating time are displayed Technical Production Information HeiTel Digital Video GmbH 2010 12 18 ...

Page 13: ... with the mobile network connection that signal strength is sufficient and that registration with the provider was successful For analyses system information and the router logs are available If a connection has been created successfully data on the registered network is given here The Signal Quality bar indicates the signal strength of the mobile network Click Refresh to update the display Techni...

Page 14: ...al additional antenna If not intermittent connectivity or considerably slower transfer speeds could result The LED indicators at the front provide information on the current operating status see TDT C1500 series device manual Technical Production Information HeiTel Digital Video GmbH 2010 14 18 ...

Page 15: ...f the LAN interface The LAN interface is administered in the router as eth0 Under Networking you will find the option Network Configuration Click Network Interfaces to view a list of all interfaces Technical Production Information HeiTel Digital Video GmbH 2010 15 18 ...

Page 16: ...r Interfaces Activated at Boot Time IP address network mask and MTU can be adapted to the existing network The IP address adapted here is the gateway address for other devices in the network of the router The DHCP service active on the router can generate collisions in a network with other DHCP services Further documentation and configuration options including tips can be found in the manual or on...

Page 17: ...f necessary contact your mobile network provider to obtain the necessary information Example Vodafone Germany DNS1 139 7 30 125 DNS2 139 7 30 126 If you wish to use the DHCP function of the C1500 router and the latter was configured correctly instead of the connection settings given above you can also activate the Obtain an IP address automatically DHCP function and if necessary also the Obtain a ...

Page 18: ...an active connection to the receiving PC To use HTconnect under Connections HTconnect the fixed IP address of the receiving PC must be entered Any port releases on the receiving side must be taken into account here More information on HTconnect http www heitel com en products heitel techniques htconnect Technical product information on HTconnect http www heitel com upload downloads en 11 technical...

Reviews: