39
Setup mix
For every gas you can set the percentage
of oxygen and helium.
Select
O2+
or
O2-
to change the
percentage of oxygen or
He+
or
He-
to change the percentage of helium.
Repeatedly push ENTER (or hold down
the ENTER button) until the required
value is displayed. For reference, the
OSTC3 displays the calculated maximum
operating depth (
MOD
) and equivalent
narcotic depth (
END
) for your mix.
Change depth
To set the operation depth for your deco
gases, select
Depth+
or
Depth-
. The
chosen operation depth will be shown
in the first line of the display. It will turn
red if the change depth is larger than
the maximum operation depth (
MOD
).
Use
Reset to MOD
to reset the value to
the MOD. The change depth can only be
configured for deco gases, not for travel
gases.