4
GENERATOR
(VI) PERIODIC MAINTENANCE
1. SPARK PLUG (per 50h or per one month)
1.1. Remove spark plug (Picture 17).
1.2. Remove carbon deposits (Picture 18).
1.3. Check for discoloration. Standard: Tan color.
1.4. Check spark plug gap. Standard: 0.7~0.8mm (Picture 19).
2. AIR FILTER (TIME: per 100h or per one month)
2.1. Remove air filter (Picture 20
①
).
2.2. Wash clearly in solvent (Picture 20
②
).
2.3. Get Motor oil (Picture 20③).
2.4. Squeeze Motor oil out (Picture 20
④
).
Warning:
Never run engine without air filter.
(Picture 17)
(Picture 18)
(Picture 19)
(Picture 20)