3
1.
For LPG (cylinder) connection, affix metal clamp on the hose coming from LPG
cylinder. Affix an edge of the hose on hose inlet connector behind the appliance by
pushing to end through heating the hose in boiled water. Afterward, bring the clamp
towards end section of the hose and tighten it with screwdriver. The gasket and hose
inlet connector required for connection is as the picture shown below.
NOTE: The regulator to be affixed on LPG cylinder should have 300mmSS feature.
2.
Natural gas connection should be done by authorized service. For natural gas
connection, place gasket in the nut at the edge of natural gas connection hose. To
install the hose on main gas pipe, turn the nut. Complete the con- nection by making
gas leakage control.
ATTENTION! Gas hose and electric connection of the appliance should not pass next
to hot areas such as back of the appliance. Gas hose should be connected by making
wide angle turns against breaking possibility. Movement of appliance whose gas
connection is made may cause gas leakage.
True False True False
VIII. GAS CONNECTION AND SAFETY
Main gas pipe
Gasket
Hose inlet connector
Metal clamp
LPG connection hose
Nut
Gasket
Main gas pipe
Natural gas connection hose