Installation
Suprasetter A52/A75 – Installation
Connection of Suprasetter to PC
Note:
The color of the Gigabit/LVDS cable can vary.
Fig. 52 GUI, Gigabit, LVDS and OLP cables
Fig. 53 Strain relief
NOTICE
Sensitive electronics
Suprasetter and PC must be
switched off
. Connect cables when machine is
deenergized only.
Connect the GUI cable (from the 2nd network
adapter in the PC) to X171 (Fig. 52/1).
Connect the Gigabit cable (from the interface
board in the PC) to X309 (Fig. 52/2).
As an alternative to the Gigabit connection, you
can also use the LVDS port (from the interface
board in the PC) on X300 (Fig. 52/3). However,
preference is to be given to the Gigabit connection.
Fasten the Gigabit or LVDS cable (and, if any, the
OLP cable from X121 (Fig. 52/4)) as shown in Fig.
53/1 with two cable ties to the chassis.
i
i