P a g e

 | 

16 

HD700 AC Drive Easy Start Guide

 

 

3  

Installation 

 

Fit and remove the internal EMC filter (Size B and C)  

 

 
 

Fit and remove the internal EMC filter (Size D and E)  

 

 

Size D: The internal EMC filter can be disconnected by removing screw 1 

 

Size D: The internal MOV can be disconnected by removing screw 2 

 

Size E: The internal EMC filter can be disconnected by removing screw 2 

 

Size E: The internal MOV can be disconnected by removing screw 1 

 
 

  

 
 
 
 
 

 

 

 

 

 

Internal EMC filter 

Internal EMC filter 

Insert link to connect 

the EMC filter 

Pull out the link to 

remove the EMC filter 

 

EMC filter 

disconnect screw 

 

 

MOV 

disconnect screw 

 

Summary of Contents for HD700 Series

Page 1: ...HD700 Easy start guide 0 4kW 90kW V1 4 0...

Page 2: ...speed electrical power drive systems Part 5 1 Safety requirements Electrical thermal and energy EN 61800 3 2004 Adjustable speed electrical power drive systems Part 3 EMC requirements and specific te...

Page 3: ...he restriction of hazardous substances These products comply with the Low Voltage Directive 2006 95 EC the Electromagnetic Compatibility EMC Directive 2004 108 EC the RoHS2 0 Directive 2011 65 EU and...

Page 4: ...e respect to the restriction of hazardous substances These products comply with the Low Voltage Directive 2006 95 EC the Electromagnetic Compatibility EMC Directive 2004 108 EC the RoHS2 0 Directive 2...

Page 5: ...minals 10 3 2 3 Typical power connections 11 3 2 4 Recommended fuses power control cables 12 3 2 5 Default control connections 13 3 2 6 Control terminals specification 14 3 2 7 EMC 15 3 2 8 RCD Compat...

Page 6: ...r the drive must be turned off for 10 minutes before unplugging the connector The HD700 is not a field repairable unit Contact the supplier of the drive The drive must be protected by the recommended...

Page 7: ...W 00150 1 5kW 01500 15kW 05500 55kW 00220 2 2kW 01850 18 5kW 07500 75kW 00400 4kW 02200 22kW 09000 90kW 00550 5 5kW 03000 30kW 2 2 Ratings Supply voltage 200 240V 10 Single Three phase 48 62Hz Model S...

Page 8: ...l duty is an industry standard name given to the current rating of a drive that is used in variable torque applications or applications that require low overload capacity Examples of low overload capa...

Page 9: ...Guide for details www hedyiad com 2 4 General Technical Data Note For full detailed technical data please refer to the HEDY website www hedyiad com Approvals UL approval E348255 CE approval Environme...

Page 10: ...ions The HD700 has an Ingress Protection rating of IP20 and therefore must be installed in a suitable enclosure according to relevant local codes or standards Mechanical dimensions and mounting Size A...

Page 11: ...P a g e 6 HD700 AC Drive Easy Start Guide 3 Installation Mechanical dimensions and mounting Size D E Mechanical dimensions and mounting Size F...

Page 12: ...HD700 AC Drive Easy Start Guide P a g e 7 3 Installation W W1 W2 D D1 Mechanical dimensions and mounting Size G...

Page 13: ...D00220 142 4 123 5 220 4 208 155 5 5 2 2 HD700 40T00220 HD700 40T00400 C HD700 20T00400 163 1 142 300 280 176 8 6 4 5 HD700 40T00550 HD700 40T00750 D HD700 40T01100 238 5 184 92 370 356 5 189 7 8 8 HD...

Page 14: ...ize G 50mm 50mm Xmm 50mm 100mm 100mm Note In vertical installations where drives are mounted above each other there should be suitable air flow to keep the drives cool Hot air from the lower drives sh...

Page 15: ...erminals layout BR DC DC U V W PE Terminal Function L1 L2 L3 N AC power supply For single phase supply on size A and B use L1 L3 N DC Positive DC bus connection DC1 For DC choke Linked to DC by busbar...

Page 16: ...ection Additional precautions must be taken to ensure that the supply to the HD700 is disconnected if a fault occurs with the internal brake circuitry or connected brake resistor Fitting of a suitably...

Page 17: ...ses A IEC gG MCB Type C Type G Type P Type G Type P Type G Type P HD700 40T01100 24 31 32 40 32 40 4 4 0 5 HD700 40T01500 31 36 40 50 40 50 6 6 0 5 HD700 40T01850 36 44 50 63 50 50 10 10 0 5 HD700 40T...

Page 18: ...Digital input 4 DI5 Digital input 5 DI6 Digital input 6 DI7 Digital input 7 24V 10V AI2 Analogue input 2 AI1 Analogue input 1 0V 0 10V DO1 Digital output 1 DO2 Digital output 2 0V 24V AO1 Analogue out...

Page 19: ...t current 50mA Analogue Input Output AI1 Programmable Analogue input1 0V 10V Input resistance 100k 0 4 mA 20mA Load resistance 188 Min Potentiometer resistance 2k Resolution 0 1 Accuracy 2 Sampling pe...

Page 20: ...e as short as possible The metal enclosure of the filter must be connected with the drives earth terminal 3 2 8 RCD residual current device compatibility and Earth leakage Single phase drives are suit...

Page 21: ...isconnected by removing screw 1 Size D The internal MOV can be disconnected by removing screw 2 Size E The internal EMC filter can be disconnected by removing screw 2 Size E The internal MOV can be di...

Page 22: ...board as shown below Note In order to ensure reliable earthing please tighten the screws 1 2 after removing the EMC filter board Fit and remove the internal EMC filter Size G The internal EMC filter c...

Page 23: ...s for illustration 1 When in Keypad control mode default pressing this key will make the drive Run 1 Pressing the Stop key will stop the drive Note P05 06 keypad lock control can be set so that this k...

Page 24: ...0 01 ESC PRG Change parameter ESC PRG 230 Change parameter value ESC PRG P00 02 ESC Left shift parameters Default display Note When the value of a parameter is changed the PRG key must be pressed to s...

Page 25: ...ble the drive 1 HD700 AC Drive Easy Start Guide quick setup guides show the quickest way to get the motor running in keypad assume that the drive has factory default parameters set commissioning in ke...

Page 26: ...witch K1 The drive will run forward the run light will come on Use the potentiometer to change the speed reference on AI1 Open the switch K1 The drive will ramp to stop and the run light will go off C...

Page 27: ...wing parameters P00 05 Reference source selector 2 Preset P00 16 Preset 1 Fixed speed required Set parameters for fixed speed Press and hold the ESC button until the display shows 0 00 2 Set the follo...

Page 28: ...hedyiad com 6 1 Easy Parameter Group Overview v v Note 1 More selections available please see parameter description for details Parameter Parameter name Parameter Parameter name P00 01 Motor rated vo...

Page 29: ...rives keypad buttons 1 Terminal Stop start forward reverse speed controlled by drive terminals 2 Serial communications Stop start forward reverse speed controlled by serial communications Note To enab...

Page 30: ...e can be adjusted by changing the level of analogue input 2 Note AI2 can only be set to voltage mode For detailed setup of AI2 please refer to Group 8 5 Serial communications In this mode users can ch...

Page 31: ...0 3 0 Stop only 0 Ramp stop The drive will ramp the motor to a stop according to the deceleration time set 1 Coasting The drive output with inhibit upon a stop command allowing the motor to coast to a...

Page 32: ...to increase Forced ventilation of the motor should be considered if running at low speeds for periods of time where airflow from the standard motor fan is ineffective Parameter Parameter name Range De...

Page 33: ...stop Run Stop Momentary open to stop DI1 Digital input 1 DI2 Digital input 2 DI3 Digital input 3 24V Fwd Rev Momentary close to run Open forward Closed reverse P00 14 1 P00 14 2 DI6 Digital input 6 En...

Page 34: ...r up then the drive will start 2 Auto Start After Power Off Mode 2 The same as Mode 1 except In terminal control mode if there is an active run signal at power up the drive will start Parameter Parame...

Page 35: ...8 Load defaults 0 1 0 Stop only 0 No action 1 Load default parameters When P00 24 is set to 1 and the PRG button is pressed all parameters are set to their factory default values For full details of a...

Page 36: ...Output phase loss Output phase lost Check motor motor cabling F006 Braking over current Brake resistor faulty or incorrect value too low a value Check the brake resistor and cabling The drive will no...

Page 37: ...o reset the drive and try again F030 Soft start circuit fault Internal drive soft start circuit failed Contact supplier of the drive F031 Main fan fault Fan blade not rotating correctly Check the fan...

Page 38: ...s acceptable then there is no need to adjust parameters The current limit is an indication not a fault If faster acceleration is required with the maximum value set in P07 03 then a larger motor and d...

Page 39: ...Notes...

Page 40: ...P00 11 AI1 mode selector P00 12 Voltage boost level Default Control Terminal Connections HD700 Run Forward Run Reverse Jog Select Preset 1 P00 16 as speed reference Enable Reset DI1 Digital input 1 DI...