background image

H E D L E R   S y s t e m l i c h t   G m b H       H e e r s t r a s s e   1 1 2       D - 6 5 5 9 4   R u n k e l   /   L a h n       w w w . h e d l e r. c o m
Te l e f o n   +   4 9   -   ( 0 )   6 4 8 2   9 1 8   1 0 0       Te l e f a x   +   4 9   -   ( 0 )   6 4 8 2   9 1 8   1 1 1       e M a i l   i n f o @ h e d l e r. c o m

Profilux

®

 LED

1400

 / Profilux

®

 LED

1400

 DMX

TECHNICAL DATA Profilux

®

 LED

1400

Type: Profilux

®

 LED

1400

 

Voltage: 110 - 230 V ~ 1,0A   50/60 Hz 

Power: 185 W LED   

Risk group: 0-RG

Color: CRI > 95 

 

Kelvin: 5600K 

 

 

Safety class system: I   

Protection category: IP30

Weight: 3600g 

 

Ambient temperature (Ta): -15° - +40° C   

Surface temperature: 85°C

Light stand attachment: 5/8“ 

Fresnel lens code: < 6507 > 

 

 

Light unit code: < 5060 >

   Safety 

clearance: 

      Position: 

 

 

 

Under any circumstances do not under-run the safety   

 

 

Tilt light unit max.

 

 

 

clearances given within the graphic to inflammable material! 

 

 

45° upwards/down-  

           wards 

in 

operation!

HEDLER

®

S y s t e m l i c h t

max. +45°

max. -45°

top

1m

0,5m

0,5m

TECHNICAL DATA Profilux

®

 LED

1400

 DMX

Type: Profilux

®

 LED

1400

 DMX 

Voltage: 110 - 230 V ~ 1,0A   50/60 Hz 

Power: 185 W LED   

Risk group: 0-RG

Color: CRI > 95 

 

Kelvin: 5600K 

 

 

Safety class system: I   

Protection category: IP30

Weight: 3600g 

 

Ambient temperature (Ta): -15° - +40° C   

Surface temperature: 85°C

Light stand attachment: 5/8“ 

Fresnel lens code: < 6507 > 

 

 

Light unit code: < 5061 >

   Safety 

clearance: 

      Position: 

 

 

 

Under any circumstances do not under-run the safety   

 

 

Tilt light unit max.

 

 

 

clearances given within the graphic to inflammable material! 

 

 

45° upwards/down-  

           wards 

in 

operation!

max. +45°

max. -45°

top

1m

0,5m

0,5m

OPERATION MANUAL

KEY BUTTONS

On the back of the light units of the HEDLER Profilux

®

 LED range there are several key buttons. By pressing them the indicated functions will 

be switched alternatingly.

Fan 100% / Automatic

100% - the fan cooling of the light units of the HEDLER Profilux

®

 LED range will be set to full power irrespective of the operating temperature; 

Automatic - the power of the fan cooling will be regulated as a function of the operating temperature.

Dimmer OFF / ON

OFF - the continuous light output power is set to maximum (100%), the setting of the rotary potentiometer will be ignored;
ON - dimming function is available by turning the rotary potentiometer.

POWER OFF / ON

OFF - light unit will be switched off or rather into stand-by-mode (if the light unit has to be currentless you have to disconnect the light unit from 
the electric power supply);
ON - light unit will be switched on with a Softstart function, the pre-set continuous light output power will be restored.
If not in use, please disconnect the light unit from the power supply completely.

STATUS-LEDs

Additionally you will find on the back of the light units of the HEDLER Profilux

®

 LED range several status LEDs. Their operation mode will be 

indicated by their glowing or blinking.

Error

Indicates an operating mode error of the HEDLER Profilux

®

 LED

1400

 / HEDLER Profilux

®

. In this case the light unit has to be checked. Please 

contact HEDLER Systemlicht GmbH directly or contact your photographic specialized dealer.
0049 (0)6482-918100
[email protected]

Please note:
If the light unit will be disconnected from the electric power supply the Error LED is glowing until the mains adapter is discharged. This is not 
indicating an error.

Summary of Contents for Profilux LED 1400

Page 1: ...sy compatibility of all HEDLER lioghtformers Interchangeable reflectors with bayonet ring can be attached in the following way Interchangeable reflectors with bayonet ring can be attached in the follo...

Page 2: ...ATION MANUAL KEY BUTTONS On the back of the light units of the HEDLER Profilux LED range there are several key buttons By pressing them the indicated functions will be switched alternatingly Fan 100 A...

Page 3: ...ly After replacing the Fresnel lens tighten its securing screws hand tight Attach the front plate at the housing and tighten the front plates four securing screws Please before taking the HEDLER Profi...

Page 4: ...nfo hedler com PLEASE NOTE SPECIAL SET UP ADVICE The light units of the HEDLER Profilux LED range has an upside and an underside setting up the light unit it is important to take care of the correct p...

Page 5: ...nit s in hospital s museum s factory factories asf with permission of the appropriate responsible public authority administration company management or business management only If not taking care of t...

Page 6: ...use a Hedler light unit with a defective safety glass a defective Pyrex cover a defective flash bulb defective bulb s and or defective fuse s Never put a Hedler light unit into operation with a defec...

Page 7: ...flectors parts of softboxes and reflex umbrellas and some accessories completely after using them and before packing them away not doing so can cause serious burnig and or the risk of sparking Not use...

Reviews: