SAFETY GLASS and BULBS and FUSES
To replace the safety glass: please, make sure that the housing of the HEDLER H25s has cooled off before interchanging the safety glass,
otherwise there is a risk of burning! Always disconnect the HEDLER H25s from the power supply before interchanging the safety glass.
Unscrew the securing screw, turn the clip sideways which is securing the Borofloat™ safety glass and remove the glass. Replace the safety glass
with a new one, turn the clip sideways into the opposite direction until it secures the Borofloat™ safety glass and thighten the securing screw.
Please, before taking the HEDLER H25s in operation, make sure that the safety glass and clip is mounted correctly and its clip is tightened.
For replacing the bulb: please, make sure that the housing of the HEDLER H25s has cooled off before interchanging the safety glass, otherwise
there is a risk of burning! Always disconnect the HEDLER H25s from the power supply before interchanging the safety glass. Unscrew the
securing screw, turn the clip sideways which is securing the Borofloat™ safety glass and remove the glass. Make sure that the bulb has cooled off,
before pulling it upward and out of the socket. Push the new bulb into the socket, observing instructions by the bulb manufacturer. Replace the
safety glass, turn the clip sideways into the opposite direction until it secures the Borofloat™ safety glass and thighten the securing screw. Please,
before taking the HEDLER H25s in operation, make sure that the safety glass is mounted correctly!
110 Volt = If you use the HEDLER H25s at a 110V power supply, please note that the Tungsten halogen bulbs and fuses have to be changed
to types which are appropriate for a voltage of 110V and a power of max. 850 Watt per bulb socket. Bulb socket type of the HEDLER H25s is:
GY, GZ 6,35.
For replacing fuse: please, make sure that the housing of the HEDLER H25s has cooled off before interchanging the fuse(s), otherwise there is
a risk of burning! Always disconnect the HEDLER H25s from the power supply before interchanging the fuse(s). Use a coin to unsrew the cap of
one of the fuse boxes, located left of the main switch on the backside of the light housing, by a counter-clockwise turn. Remove the spent fuse and
replace it by a new one of the appropriate type. Closing is done by pressing down the lid and screwing the cap into it´s place by a clockwise turn.
The HEDLER H25s can be equipped with Tungsten halogen bulbs of a different continuous light output power. Within the chart below you will
find the information, which Tungsten halogen bulb(s) - appropriate fuse(s) - combination has to be used. Please, use bulbs with the appropriate
fuse(s) only.
Bulbs and fuses
Halogen bulbs
Watts
Volts
average life time / h.
Kelvin
Fuse
Code
Bulb-Type
< 64502 >
150
230
25
3200
F 2 A
< 1048 >
< 64515 >
300
230
15
3400
F 2 A
< 1048 >
< 64516 >
300
230
75
3200
F 2 A
< 1048 >
< 64540 >
650
230
15
3400
F 4 A
< 1045 >
< 64575 >
1000
230
15
3400
F 6,3 A
< 1039 >
< 64576 >
1000
230
75
3200
F 6,3 A
< 1039 >
TECHNISCHE DATEN H25s
Type: H25s
Voltage: 110 - 230 V ~ 2x 6,3A 50/60 Hz
Power: max. 2000 W
Fuse: 2x 6,3A
Color: CRI > 97
Kelvin: 3200K
Safety class system: I
Protection category: IP30
Risk group: 1-RG
Weight: 2450g
Ambient temperature (Ta): -15° - +40° C
Surface temperature: 120°C
Light stand attachment: 5/8“
Safety glass code: < 2051 >
Light unit code: < 2511 >
Safety clearance:
Position:
Under any circumstances do not under-run the safety
Tilt light unit max.
clearances given within the graphic to inflammable material!
45° upwards/down-
wards in operation!
max. +45°
max. -45°
0°
top
1m
0,5m
0,5m