Hedler H25s Operation Manual Download Page 2

H E D L E R   S y s t e m l i c h t   G m b H       H e e r s t r a s s e   1 1 2       D - 6 5 5 9 4   R u n k e l   /   L a h n       w w w . h e d l e r . c o m
T e l e f o n   +   4 9   -   ( 0 )   6 4 8 2   9 1 8   1 0 0       T e l e f a x   +   4 9   -   ( 0 )   6 4 8 2   9 1 8   1 1 1       e M a i l   i n f o @ h e d l e r . c o m

Halogen H25s

HEDLER

®

S y s t e m l i c h t

OPERATION MANUAL

SAFETY GLASS and BULBS and FUSES

To replace the safety glass: please, make sure that the housing of the HEDLER H25s has cooled off before interchanging the safety glass, 
otherwise there is a risk of burning! Always disconnect the HEDLER H25s from the power supply before interchanging the safety glass. 
Unscrew the securing screw, turn the clip sideways which is securing the Borofloat™ safety glass and remove the glass. Replace the safety glass 
with a new one, turn the clip sideways into the opposite direction until it secures the Borofloat™ safety glass and thighten the securing screw. 
Please, before taking the HEDLER H25s in operation, make sure that the safety glass and clip is mounted correctly and its clip is tightened.

For replacing the bulb: please, make sure that the housing of the HEDLER H25s has cooled off before interchanging the safety glass, otherwise 
there is a risk of burning! Always disconnect the HEDLER H25s from the power supply before interchanging the safety glass. Unscrew the 
securing screw, turn the clip sideways which is securing the Borofloat™ safety glass and remove the glass. Make sure that the bulb has cooled off, 
before pulling it upward and out of the socket. Push the new bulb into the socket, observing instructions by the bulb manufacturer. Replace the 
safety glass, turn the clip sideways into the opposite direction until it secures the Borofloat™ safety glass and thighten the securing screw. Please, 
before taking the HEDLER H25s in operation, make sure that the safety glass is mounted correctly!

110 Volt = If you use the HEDLER H25s at a 110V power supply, please note that the Tungsten halogen bulbs and fuses have to be changed 
to types which are appropriate for a voltage of 110V and a power of max. 850 Watt per bulb socket. Bulb socket type of the HEDLER H25s is: 
GY, GZ 6,35.

For replacing fuse: please, make sure that the housing of the HEDLER H25s has cooled off before interchanging the fuse(s), otherwise there is 
a risk of burning! Always disconnect the HEDLER H25s from the power supply before interchanging the fuse(s). Use a coin to unsrew the cap of 
one of the fuse boxes, located left of the main switch on the backside of the light housing, by a counter-clockwise turn. Remove the spent fuse and 
replace it by a new one of the appropriate type. Closing is done by pressing down the lid and screwing the cap into it´s place by a clockwise turn.

The HEDLER H25s can be equipped with Tungsten halogen bulbs of a different continuous light output power. Within the chart below you will 
find the information, which Tungsten halogen bulb(s) - appropriate fuse(s) - combination has to be used. Please, use bulbs with the appropriate 
fuse(s) only.

Bulbs and fuses

Halogen bulbs

Watts

Volts

average life time / h.

Kelvin

Fuse

Code

Bulb-Type

< 64502 >

150

230

25

3200

F 2 A

< 1048 >

< 64515 >

300

230

15

3400

F 2 A

< 1048 >

< 64516 >

300

230

75

3200

F 2 A

< 1048 >

< 64540 >

650

230

15

3400

F 4 A

< 1045 >

< 64575 >

1000

230

15

3400

F 6,3 A

< 1039 >

< 64576 >

1000

230

75

3200

F 6,3 A

< 1039 >

TECHNISCHE DATEN H25s

Type: H25s 

 

Voltage: 110 - 230 V ~ 2x 6,3A   50/60 Hz   

Power: max. 2000 W   

Fuse: 2x 6,3A

Color: CRI > 97 

 

Kelvin: 3200K 

Safety class system: I   

Protection category: IP30 

Risk group: 1-RG

Weight: 2450g 

 

Ambient temperature (Ta): -15° - +40° C   

Surface temperature: 120°C

Light stand attachment: 5/8“ 

Safety glass code: < 2051 > 

 

 

Light unit code: < 2511 >

 

 

 

Safety clearance: 

 

 

 

 

 

 

Position: 

 

 

 

Under any circumstances do not under-run the safety   

 

 

Tilt light unit max.

 

 

 

clearances given within the graphic to inflammable material! 

 

 

45° upwards/down-  

 

 

 

 

 

 

 

 

 

 

 

wards in operation!

max. +45°

max. -45°

top

1m

0,5m

0,5m