Description

1

Photocell

2

Sync cord socket 6,3 mm

3

0
1

Main switch HEDLER FP 250
HEDLER FP 250 is switched off
HEDLER FP 250 is switched on

4

Flash bulb fuse FF 4 A - please refer to page 4: 

Necessary precautions

 and 

To replace the fuse FF 4 A (flash 

bulb)

: ALWAYS use FF 4 A  Replacement Fuses supplied by Hedler Systemlicht GmbH

5

Power cord socket - use only a power cord that is supplied by Hedler Systemlicht GmbH to put your HEDLER FP 250 
into operation

6

Digital Indicator - 1/10 f-stop graded - to adjust the flash output power very precisely between two flash lights

7

Test switch - flash firing manually, refer to page 1 for further information about function

8

off
on

blinking

Photocell switch
Photocell is switched off
Photocell is switched on; the FP 250 will only be released if it receives a strong enough light or IR light impulse
Photocell is switched on and ignores some camera´s metering pre-flash; the FP 250 will be released when the 
camera´s main flash is released (if the main flash is released not later than 1/500 seconds after the pre-flash
was released)

9

off
on

blinking

Acoustic Control switch
Acoustic Control is switched off
Acoustic Control is switched on - a repeated tone is followed by one longer tone which indicates the FP 250 is ready 
for flash release after changing the flash light output power or after successfully releasing a flash
Acoustical control is switched on - one single tone indicates the FP 250 is ready for flash release after changing the flash 
light output power or after successfully releasing a flash

10

and

11

Flash light output power control button plus and minus - allows the variable setting of the flash units power over 4 
f-stops

Example:

• the digital indicator of your HEDLER FP 250 shows 3, your light meter indicates f-stop 8 and 3/10 (=f-stop 9)
• for your actual lighting idea you need f-stop 11 and 3/10 (=f-stop 13)
• press the flash light output power control plus button until the digital indicator shows 4 instead of 3
• please do another light metering
• your light meter should display approx. f-stop 11 and 3/10

Please note:

Because of your Studio situation (colour of the wall, size, reflections, etc.) and the combination with additional flash 
light units, it may happen that a changing of the flash light output power (which will be displayed additionally by the 
digital indicator) does not lead to the expected f-stop increase/decrease. This is not an error of the system but the 
result of the conditions within the situation. In that case please adjust the flash light output power rotary control until 
light metering shows the needed f-stop value.

12

off
on

blinking

Pilot Set switch (=Modeling light switch) 
Pilot light is switched off (prevents possible reflections on shiny materials caused by the pilot light)
Pilot light is switched on + adjusted proportionally to flash light output power without flash re-/discharging indication
Pilot light is switched on + adjusted proportionally to flash light output power with flash re-/discharging indication (if 
the flash light unit has to be re-/discharged after changing the flash light output power or after flash firing the pilot light 
is automatically turned off until the FP 250 is ready for flash firing)

13

off
on

blinking

Pilot Range switch (Pilot light output power additional function)
Pilot light output power additional function is switched off
Pilot light output power additional function is switched on - pilot light output power is set to 100% without changing 
the actual flash light output power setting
Pilot light output power additional function is switched on - pilot light output power is set to 50% without changing the 
actual flash light output power setting

14

Wing bolt incl. friction brake - open the wing bolt by a counter-clockwise turn and the tilting of the FP 250 can be 
adjusted to your required lighting angle. Always secure the wing bolt and friction brake with a clockwise turn to avoid 
unwanted movement or damage to the HEDLER FP 250 and/or injury to the user

15

Spring-secured pre-locking - is used to prevent unwanted disconnecting from a light stand or a wall boom with a 5/8“ 
male adapter; to disconnect you must press the pin and lift the complete light unit at the same time

16

5/8” Quick-Lock Light Stand Attachment - allows use with every secure and sufficiently strong light stand (ALWAYS 
check the light stand´s maximum load capicity) with 5/8“ male adapter

17

Wing bolt - open the wing bolt by a counter-clockwise turn and the horizontal rotating of the FP 250 can be adjusted 
to the required position. ALWAYS secure the wing bolt with a clockwise turn to avoid any unwanted movement of the 
FP 250 around the horizontal axis (if connected to an upright standing light stand)

Reviews: