7. Maintenance.

The HG Skin cleaner is manufactured with maintenance free bearings and  

strained belts in order to minimize the maintenance of the machine. However 

you still have to clean the belts and the brushes, which are wearing parts, 

and they have to be changed after need. 

7.1 Cleaning.

You can clean the HG Skin cleaner with air or water. By cleaning with water, 

avoid flushing directly on the operating box and the engine.

When you clean around the brushes, first disconnect the electric and the air 

connection. Dismount the bolts by the 8 marks and remove the screens.    

Summary of Contents for 2005 - 20

Page 1: ...13 07 2018 Model 2005 20xx USERS MANUAL HG SKIN CLEANER...

Page 2: ...3 3 1 Pictorial explains 4 4 Operating terms 5 5 Connection of the skin cleaner 6 5 1 Connection of voltage 6 5 2 Connection of suction 7 5 3 Connection of compressed air 7 5 4 Relocation 7 6 Operati...

Page 3: ...of security and working environment 2 1 Warranty There is 1 year of warranty on the HG Skin cleaner Defect parts can be replaced if the defect can be assigned to a fabrication error Errors which can...

Page 4: ...Because of life danger the box must not be opened by unauthorized employees DANGER ROTATING PARTS Avoid touching the movable parts of the machine with fingers or clothing this can cause damages on the...

Page 5: ...Telephone 0045 75 89 12 44 IMPROVING YOUR FUR BUSINESS 5 4 Operating terms 1 Start Stop 2 Emergency stop 3 Air connection piece for skin blowing 4 Screw for adjustment of legs 2 4 3 1...

Page 6: ...cleaner is fit with a 16A CEE socket 1 to which 400 volt is connected with earth The engine has a maximum consumption during running on 1 1A For control and turning of direction of rotation see secti...

Page 7: ...r backwards Then tighten up the screws again Pay attention that the machine does not tip over 5 3 Connection of compressed air Connection of compressed air is free If you do not use the connection pie...

Page 8: ...hine again start and check the rotation direction again Never use the machine without suction then dust and sawdust will whirl around in the room which gives a bad cleaning and it is bad for the healt...

Page 9: ...wever you still have to clean the belts and the brushes which are wearing parts and they have to be changed after need 7 1 Cleaning You can clean the HG Skin cleaner with air or water By cleaning with...

Page 10: ...12 brushes is mounted with 3mm unbrako bolts Screw off the bolts remove the old brush and mount the new brush with the bolts Repeat this with the other 12 brushes 4 Mount the screens again 5 Connect...

Page 11: ...specifications Electric supply 400 V Size of engine 0 37 kW Electric connection 16A CEE Compressed air 7 bar Air connection Quick fit coupling Cejn 320 Brushing speed 1400 rotation min Dimensions Len...

Page 12: ...lf 45 75 89 12 44 www hedensted gruppen dk herewith declares that HG Skin cleaner Type number 207110 is in conformity with the provision of The Machinery Directive 2006 42 EC The Low Voltage Directive...