background image

 

4  

 

TT-MTM2 CONTROLLER INSTALLATION GUIDE 

Controller Wiring Example

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The TT-MTM2 controller requires sufficient air circulation in order to provide continuous operation on the high 
power load setting.  The vents must remain clear at all times; never block or cover the vents. 
 
An ideal controller installation will provide significant space around the back of the controller. Installing into 
restricted spaces, such as brick walls, may result in overheating if adequate ventilation is not provided. 

 

A

C

TI

V

E

 

EA

R

TH

 

N

E

U

TR

A

N

 

220-240V~ 
50Hz Supply 

GANG 
 BOX 

Load 

16A Max 

Summary of Contents for TT-MTM2

Page 1: ...PRODUCT MANUAL TT MTM2 Hard Wired Controller with Remote ...

Page 2: ...ere may be a requirement to control the heat output of the heater The controller has 3 settings they are High Medium and Low The controller allows a combination of the multiple timer 1 2 4 hour and heat outputs High Medium Low The controller comes with a remote control unit which provides convenient control of the heater power output and timer functions Controlling multiple heaters It is possible ...

Page 3: ...rm up After this time it will operate as selected Safety The TT MTM2 controller is to be mounted indoors It needs to be away from wet conditions Ensure the connections are properly connected The controller needs to be installed according to your local wiring guidelines and regulations Do not allow any cables furnishings flammable materials or other items to obstruct the vents of the controller Nev...

Page 4: ...h power load setting The vents must remain clear at all times never block or cover the vents An ideal controller installation will provide significant space around the back of the controller Installing into restricted spaces such as brick walls may result in overheating if adequate ventilation is not provided ACTIVE EARTH NEUTRAL L N 220 240V 50Hz Supply GANG BOX Load 16A Max ...

Page 5: ...he maximum current rating of 16A must not be ex ceeded For direct wiring to the controller the maximum is generally one heater unit unless the combined maximum cur rent is less than 16A For example 2x THH1800A can be connected directly to the controller Below are example circuits indicating potential installation configurations Always check with your electrician and ensure all wiring is in accorda...

Page 6: ... for more detail Below is an example circuit indicating one potential installation configuration Always check with your electrician and ensure all wiring is in accordance with local regulations Note to electrician The controller modulates the heat output using a timed on timed off function The controller does not modulate the voltage output A relay is therefore suitable for this application ...

Page 7: ...orized representative of Thermofilm Thermofilm does not participate in any site related costs or labour expenses incidental to replacement of parts repairing removing installing servicing transportation or handling of parts to complete products and assumes no liability on parts repaired or replaced without written authorisation Thermofilm shall not be liable for any default or delay in performance...

Reviews: