Heater wiring schematic diagrams 

 
The HEATSTRIP

®

 heater is required to be fitted with an "ON/OFF" isolation switch and can also be controlled with the use 

of a timer type control. It is recommended to use the TT-MTM Wall Controller for maximum performance and control 
options.  Ensure the unit is turned OFF after use.   
 
For direct wiring to the controller, the maximum is one heater unit unless it is two THH1500A.  
 
For multiple units from one wall controller it is recommended to talk your electrician who will use a relay or contactor.  

2 x THH1500A

THH1500A

HEATER

FIELD WIRING

IN SWITCHBOARD

TT-MTM

WALL CONTROLLER

MAXIMUM 15A

ACTIVE

NEUTRAL
EARTH

6.3A

6.3A

THH1500A

HEATER

1x THH2400A

THH2400A

HEATER

FIELD WIRING

IN SWITCHBOARD

TT-MTM

WALL CONTROLLER

MAXIMUM 15A

ACTIVE

NEUTRAL
EARTH

10A

1x THH3200A

THH3200A

HEATER

FIELD WIRING

IN SWITCHBOARD

TT-MTM

WALL CONTROLLER

MAXIMUM 15A

ACTIVE

NEUTRAL
EARTH

13.3A

RCD

CIRCUIT

BREAKER

RCD

CIRCUIT

BREAKER

RCD

CIRCUIT

BREAKER

ISOLATOR

ISOLATOR

ISOLATOR

Summary of Contents for THH-A series

Page 1: ...R A D I A N T O U T D O O R H E A T E R S Product Manual HEATSTRIP Classic THH A The heater that is a design feature ...

Page 2: ...ions Below is a list of some common applications to assist with the selection of the most effective and efficient series This will assist in selecting the ideal range prior to proceeding further This is a general guide only please refer to the Product Manual for each product for more information HEATSTRIP Classic THH A models is a premium high temperature heater and is primarily used for outdoor r...

Page 3: ...TSTRIP does not emit light or glow when in use blending elegantly into your décor Ceiling wall and umbrella mounting options ensure that your valuable floor and table space is not wasted Efficient cost effective electric heating The innovative design of the HEATSTRIP enables comfortable and even heat dispersion from the heater surface with minimal operating costs Design flexibility Four HEATSTRIP ...

Page 4: ...th high surface area profiled alloy OUTPUT Refer to model code chart above POWER 230 240 Volts Nominal at 50 60 Hertz Single Phase CONNECTION 3 Core Cable 2 5mm2 APPROVALS AUSTRALIA NZ MOUNTING HEIGHT MINIMUM RECOMMENDED MAXIMUM 2 1 m 2 3 m to 2 5 m 2 7 m in a fully enclosed outdoor area For higher ceiling heights units can be lowered using optional bracket kits or refer to the Heatstrip Max range...

Page 5: ...S 100V YES 200V YES 200V THH1800AUK UNITED KINGDOM 240 1800 7 5 1104x 165 x 48 6 1000 YES 240V THH3200AEU EUROPE 230 3200 13 3 1774 x 165 x 48 8 500 NO THH1500AUK UNITED KINGDOM 240 1500 6 3 924 x 165 x 48 5 1000 YES 240V THHA1500UL NORTH AMERICA 115 1500 6 3 924 x 165 x 115 5 NONE NO THHA2400UL NORTH AMERICA 240 2400 10 924 x 165 x 115 7 NONE NO THHA3200UL NORTH AMERICA 240 3200 13 3 924 x 165 x ...

Page 6: ...urs 2 78 per hour 2 Electricity rate of 20 0 cents kWh 3 All calculations are excluding GST 1 5kW x 0 20 cents 0 30 or 30 cents per hour 1 8kW x 0 20 cents 0 36 or 36 cents per hour 2 4kW x 0 20 cents 0 48 or 48 cents per hour 3 2kW x 0 20 cents 0 64 or 64 cents per hour Calculations of yearly running cost are based on 180 hours usage 180 hours x 2 78 500 40 yearly running cost for outdoor gas hea...

Page 7: ... the high use areas such as over outdoor tables BBQ s lounges assembly lines or in door workstations Often it is more practical and efficient to spot heat these areas Spot heating will help to reduce the initial capital cost as well as the running costs Spot heating will allow the area to be zoned meaning heating only the areas that are being used such as tables in a restaurant or outdoor alfresco...

Page 8: ...ights and if possible positioning the heater directly above the area to be heated Also the temperature ie surface temperature is the same for all 4 models regardless of the wattage However as the size increases and the length of the unit increases the radiant footprint will be larger The below diagrams show the approximate heating area for each model based on both an indoor and outdoor enclosed en...

Page 9: ...eating a minimum heating capacity of 400W m2 is recommended The below table outlines the coverage of each HEATSTRIP Classic model in m2 based on 3 different scenarios with direct overhead mounting For example for an outdoor area that is protected from prevailing winds by walls café blinds etc Model THH 1500A will cover 3m2 and Model THH2400A will cover 4 8m2 For angled wall mounting applications t...

Page 10: ...thod is to spot heat a table or similar area The below diagrams provides an easy selection guide for the approximate model and quantity of heaters required to heat common residential table settings Selections are based on HEATSTRIP Classic being mounted at 2 4m from the floor and an undercover fully enclosed outdoor area ...

Page 11: ... of the optional accessories to reduce the height of the heater to 2 3m 2 5 m This will increase the effectiveness of your HEATSTRIP Refer to the Mounting Accessory section for more information Electrical connections GPO s should not be located at the back of the heater They should be located outside the physical footprint of the units to minimize heat build up behind the units If the heater is to...

Page 12: ...n 1000 Min 2100 Min LIGHT FAN OR SPRINKLER MUST NOT BE BELOW THE HEATER CEILING FLOOR Wall SURFACE BELOW HEATER SURFACE BELOW HEATER 1500 Min 1000 Min 2100 Min CEILING FLOOR Wall 60 Min 60 Min LIGHT FAN OR SPRINKLER MUST NOT BE BELOW THE HEATER Installation location the below diagrams confirm the minimum recommended clearances Angled Ceiling Installation Ceiling Installation Angled Wall Installati...

Page 13: ...re range of mounting options available refer to below diagrams The HEATSTRIP Classic can be mounted directly to the ceiling angled downwards on a wall fitted flush with the ceiling suspended on chains or poles attached to beams or poles mounted end to end or 2 units together Refer to the following pages for more detailed information on each mounting option STANDARD MOUNTING BRACKETS INCLUDED IN BO...

Page 14: ...th a pair of standard mounting brackets These adjustable brackets allow direct ceiling or wall mount and come with preset angle options of parallel 22 5 and 45 PART No PACKAGED DIMENSIONS mm WEIGHT kg ZBRAK 103 125 x 150 x 40 0 2 MATERIALS ALLOY MODEL B MINIMUM DISTANCE mm THH3200A 1470 THH2400A 1000 THH1500A 550 THH1800A 710 B 165 5 103 41 100 Ø7 ...

Page 15: ...vironment Maximum mounting heights should be strictly followed otherwise the performance of the units may be reduced The facia of the enclosure is manufactured from 316 Stainless Steel and the rear casing is black zinc coated steel Please refer to the Installation Manual for more detailed installation information 42 172 1330 125 1412 1470 221 1420 230 280 SUITABLE FOR MODELS HOLE CUTOUT DIMENSIONS...

Page 16: ... x 50 0 5 MATERIALS 316 SS 70mm Maximum 42mm MAX 5mm HARDWARE The optional Pole Beam mounting bracket kit can be used to mount HEATSTRIP Classic onto wooden beams rafters poles umbrellas struts etc 20 MINIMUM 175 MAXIMUM BEAM or POLE BEAM or POLE SCREWS NOT INCLUDED SCREWS NOT INCLUDED BEAM or POLE SCREWS NOT INCLUDED TRANSVERSE MOUNTED WIDE CENTERED MOUNT NARROW CENTERED MOUNT OFFSET MOUNT BEAM o...

Page 17: ...units of HEATSTRIP Classic to be mounted side by side either in parallel or angled as per the diagram on the right This is ideal for applications when a wider heat coverage is required or when there is mounting restrictions limitations such as running between 2 rows of tables etc The Twin Mount bracket can also be used with the Extension Mount bracket and Pole Kit to lower the units from a high ce...

Page 18: ...mum heat performance and aesthetic appeal This is ideal for applications such as long rows of tables and assembly lines where a constant heat coverage is required The bracket allows for a 50mm gap between units and an opening for the power connection As per the dia gram below units should be mounted with the power leads together The end to end bracket can be used with either the standard ceiling w...

Page 19: ...nded to lower the heaters to an ideal mounting height of 2 3m 2 5m The bracket is designed to be used with chains or wires There can be multiple chain wire arrangement options as per the below diagram Note chains or cable are not supplied with the heaters PART No PACKAGED DIMENSIONS mm WEIGHT kg THHAC 002 300 x 150 x 50 1 MATERIALS 316 SS THHAC 003 1200 x 120 x 50 2 316 SS SUITABLE FOR MODELS THH1...

Page 20: ...ion pole screws and brackets Kit includes 2x1200mm extension pole screws and brackets The Extension Mount bracket allows HEATSTRIP Classic units to be lowered from high ceilings using rigid connections The brackets are for use with 25mm x 25mm x 1mm tube SHS and can be supplied as brackets only for customising the length of the drop on site or supplied as a complete kit with brackets pre cut poles...

Page 21: ...models can be connected to the horizontal umbrellas struts using the Pole Beam mounting kit THHAC 001 Quick reference guide for spot heating common permanent umbrella structure 9m2 umbrella area 4 x THH 1500A 12 m2 umbrella area 6 x THH 1500A or 4 x THH 1800A 16 m2 umbrella area 8 x THH 1500A or 6 x THH 1800A This is a guide only For more detailed information please contact the um brella manufactu...

Page 22: ...ngs High Medium and Low The controller allows a combination of the multiple timer 1 2 4 hour and heat outputs High Medium Low The default operation is continuous operation at full temperature Controlling multiple units It is possible to use one wall controller to control multiple heaters The wall controller is rated at 14 Amps and 240 volts For larger current draw it is recommended that you talk t...

Page 23: ...he bath or shower The heater needs to be installed as per the installation instructions paying special attention to the minimum clearances The heater needs to be mounted on a rigid bracket or fixing The heater must not be mounted immediately below or in front of a socket outlet In case of a heater fault or damaged supply lead the appliance should be returned to the point of purchase for return to ...

Page 24: ...ter unit unless it is two THH1500A For multiple units from one wall controller it is recommended to talk your electrician who will use a relay or contactor 2 x THH1500A THH1500A HEATER FIELD WIRING IN SWITCHBOARD TT MTM WALL CONTROLLER MAXIMUM 15A ACTIVE NEUTRAL EARTH 6 3A 6 3A THH1500A HEATER 1x THH2400A THH2400A HEATER FIELD WIRING IN SWITCHBOARD TT MTM WALL CONTROLLER MAXIMUM 15A ACTIVE NEUTRAL...

Page 25: ...H3200A HEATER 13 3A THH3200A HEATER 13 3A THH3200A HEATER RCD CIRCUIT BREAKER ISOLATOR RELAY ACTIVE NEUTRAL EARTH ACTIVE NEUTRAL EARTH ACTIVE NEUTRAL EARTH ISOLATOR ISOLATOR ISOLATOR 15 Amp 15 Amp 15 Amp 15 Amp Heater wiring schematic diagrams with relays When more heating units need to be connected from the same switch a relay is needed It is recommended that you talk to your electrician for more...

Page 26: ...ute a warrantable event No products or components will be supplied in advance of an examination of the faulty product or components by Thermofilm or an authorized representative of Thermofilm Thermofilm does not participate in any site related costs or labour expenses incidental to replacement of parts repairing removing installing servicing transportation or handling of parts to complete products...

Reviews: