Operation 

 

Press 

On/Off

” 

button to turn power on and off. 

 

Once turned on, the controller will default to High power setting and will be permanently on (no 
timer function). Press 

POWER

” 

button to select the desired power setting by cycling through 

HIGH—MEDIUM

-

LOW. When power setting is at high the controller will provide continuous 

power.  When power setting is at 

MEDIUM

” 

or 

LOW

” 

the output alternates between being on 

and off so that it delivers a lower output to the heater.  Press 

TIMER

” 

button to set the timer to 

1,2,4 hours or permanently on. When permanently on, one of the TIMER LED

s will be illuminat-

ed. Once the timer is selected, the timer will be started immediately. When the timer has end-
ed, power will turn off and all LED

s will also  turn off. 

 

 

Thermal Cut

-

Out Protection 

 

This controller is protected by a thermal cut

-

out switch. This switch is activated when the 

 

temperature of the controller is too high. The controller will cut all power until it has sufficiently 
cooled. Once it cools the unit will continue working as usual. 

 

 

Warm Up Mode 

 

The controller is programmed to operate continuously (High setting) for the first 15 minutes of 
operation regarding less of the selected power setting, this is to allow time for the heater to 
warm up. After this time it will operate as selected. 

 

 

Safety

 

 

The TT

-

MTM controller is to be mounted indoors it needs to be away from wet conditions. 

 

Ensure the connections are properly connected. The controller needs to be installed according 
to your local wiring guidelines and regulations . Do not allow any cables, furnishings, flammable 
materials or other items to obstruct the vents of the controller. Never block the air vents of the 
controller. 

 

Never block the air vents of the controller. Do not put anything in the vents of the controller. 

 

The appliance is not intended for use by persons (Including children) with  reduced physical, 
sensory or intellectual capabilities, or lack of experience and knowledge , unless they have been 
given supervision or instruction concerning use of the appliance by person responsible for their 
safety. Children should be supervised to ensure they do not play with the appliance. 

 

Maintenance 

 

The TT

-

MTM Controller is made from durable materials, however regular care and maintenance 

of your controller will help prolong the life of the product.  It is recommended that you dust the 
controller to keep the surface clean. Cleaning at least every three months will reduce the 
amount of dust build up and keep it looking at its best. Do not use any abrasive materials or 
product s to clean the controller, this includes solvents, citrus based cleaners or other harsh 
cleaning products. Do not use water or a damp cloth to clean the controller. The remote uses a 
CR2025 3V lithium battery. If the red light on the remote stops working then change the battery. 

 

Summary of Contents for INTENSE THY2200

Page 1: ...Ph 03 9562 3455 E sales thermofilm com au HEATSTRIP Intense Intense White THY THYW Intense THY THYW Product Manual www heatstrip com au ...

Page 2: ...rosion protection Built from corrosion resistant alloy it is suitable for use in most applications including difficult corrosive environments such as coastal areas Multi Purpose Mounting Options The HEATSTRIP Intense is supplied with flexible mounting options The standard bracket will allow both ceiling and wall mounting at various angles as well as suspension by chains wires and metal rods DIY Th...

Page 3: ...TION 3 Core Cable 2 5mm2 APPROVALS AUSTRALIA NZ EU MOUNTING HEIGHT MINIMUM RECOMMENDED MAXIMUM 2 1 m 2 3 m 2 5 m 2 8m Outdoors and 3m Indoors For higher ceiling heights units can be lowered using optional brackets kits MOUNTING OPTIONS Suitable for ceiling wall and beam mounting as well as suspension by chains wires using standard brackets Optional mounting accessories include extension mount pole...

Page 4: ...les BBQ s lounges assembly lines or indoor work stations Often it is more practical and efficient to spot heat these areas Spot heating will help to reduce the initial capital cost as well as the on going running costs Spot heating will allow the area to be zoned meaning heating only the areas that are being used such as tables in a restaurant or outdoor alfresco area The top diagram shows how HEA...

Page 5: ...winds by walls café blinds etc e g outdoor enclosed This data is based on direct overhead ceiling mounting If the heaters are wall mounted the radiant footprint will be reduced Above data is based on direct overhead ceiling mounting If the heaters are wall mounted the radiant footprint may be reduced The below diagrams show the approximate heating area for each model based on both an indoor protec...

Page 6: ...majority of outdoor applications the most effective method is to spot heat a table or similar area The diagrams below provides an easy selection guide for the approximate model and quantity of heaters required to heat common resi dential table settings Selection are based on HEATSTRIP Intense being mounted at 2 4m from the floor in a fully enclosed undercover outdoor area THY2200 2x THY2200 2x THY...

Page 7: ... 3m 2 5m This will increase the effectiveness of your HEATSTRIP Refer to the Mounting Accessory section for more information Electrical connections GPO s should not be located at the back of the heater They should be located outside the physical footprint of the units to minimize heat build up behind the units The HEATSTRIP Intense is not suitable for mounting on an incline along the length This M...

Page 8: ...allation Ceiling Installation Angled Ceiling Installation Lights fans and sprinklers must NOT be below heater Surface Below Heater Lights fans and sprinklers must NOT be below heater Surface Below Heater Lights fans and sprinklers must NOT be below heater Surface Below Heater 300 150 300 150 1000 min ...

Page 9: ... to the ceiling flush mounted into the ceiling angled downwards on a wall suspended on chains poles or attached to beams and rafters Refer to the following pages for more detailed information on each mounting option Optional Mounting Accessories Installation options with standard bracket Chain not included Standard Ceiling Bracket Beam Pole Mounting Using standard bracket Chain Wire Mounting Using...

Page 10: ...ith chains The brackets need to be mounted onto a secure frame or wall with a minimum distance between the two brackets The minimum distance B for each model is listed on the next page All dimensions shown below are in mm When completing the installation ensure all screws are tight and unit is secure Note When suspension mounting chains are not included Standard Mounting Bracket PART No PACKAGED D...

Page 11: ...tion and secure the 2 locking brackets to the mounting brackets using the screws provided Make sure the 2 pins on the locking bracket engage with the matching holes in the mounting bracket The pins will allow for both horizontal or angle mounting as required Tighten all screws and tighten the round nut at the top of the bracket so it locks onto the top part of the mounting bracket NOTE The standar...

Page 12: ...le THEAC 044 THYAC 049 900 x 150 x 50 0 55 Aluminium Kit includes 2x900mm extension pole THEAC 045 THYAC 050 1200 x 150 x 50 0 71 Aluminium Kit includes 2x1200mm extension THEAC 046 The Extension Mount bracket allows HEATSTRIP Intense units to be lowered from high ceilings using rigid connections The standard length options as part of the kit are 300mm 600mm 900mm and 1200mm The extension mount br...

Page 13: ...ly followed otherwise the performance of the units may be reduced A minimum clearance of 200mm behind the enclosure must be provided The enclosure for the THY2200 THY3200 is manufactured from black powder coated steel with a black fascia The enclosure for the THY2200W THY3200W is manufactured from black powder coated steel with an off white fascia SUITABLE FOR MODEL PART No HOLE CUTOUT DIMENSIONS ...

Page 14: ...ocket outlet Design Features The TT MTR PLUG provides an easy means of remotely turning on appliances that are normally permanently con nected to a standard wall socket An easily selected 1 hour 2 hour and 4 hour timer function accessible on both the wall unit and re mote Programmable remote control unit capable of controlling multiple units Remote battery CR2025 3V Lithium Remote range 10m Wall s...

Page 15: ... alfresco areas restaurant dining assembly line production etc When continuous heat is not required The timer also reduces the likelihood of heaters being inadvertently left turned on Depending on the ambient temperature there may be a requirement to control the heat output of the heater The controller has 3 settings they are High Medium and Low The controller allows a combination of the multiple ...

Page 16: ... controller is to be mounted indoors it needs to be away from wet conditions Ensure the connections are properly connected The controller needs to be installed according to your local wiring guidelines and regulations Do not allow any cables furnishings flammable materials or other items to obstruct the vents of the controller Never block the air vents of the controller Never block the air vents o...

Page 17: ...ting The vents must always remain clear never block or cover the vents An ideal controller installation will provide significant space around the back of the controller In stalling into restricted spaces such as brick walls may result in overheating if adequate ventilation is not provided TT MTM2 Controller Installation Guide ...

Page 18: ...g to the controller the maximum is generally on heater unit unless the combined maximum current is less than 16A For example 2x THH1800A can be connected directly to the controller Below are example circuits indicating potential installation configurations Always check with your electrician and ensure all wiring is in accordance with local regulations Heater wiring schematic diagrams 1x THY3200 or...

Page 19: ...ention to the minimum clearances The heater needs to be mounted on a rigid bracket or fixing The heater must not be mounted immediately below or in front of a socket outlet In case of a heater fault or damaged supply lead the appliance should be returned to the point of purchase for return to Thermofilm for repair Maintenance The HEATSTRIP is made from durable materials however regular care and ma...

Page 20: ...ent No products or components will be supplied in advance of an examination of the faulty product or components by Thermofilm or an authorized representative of Thermofilm Thermofilm does not participate in any site related costs or labour expenses incidental to replacement of parts repairing removing installing servicing transportation or handling of parts to complete products and assumes no liab...

Reviews: