17
HEATSTRIP Wall Mounting Kit - (THHAC-028)
Installation Location
- The below diagram outlines the recommended clearances.
Note: The minimum height from the ground to bottom of the bracket is 2.1m, and the maximum height from
the ground to the end of the heater is 2.7m. We recommend a mounting height of 2.3 to 2.5m.
2100mm Min.
DIMENSION (mm)
WEIGHT (Kg)
MATERIALS
550 (L) x 165 (W) x 250 (H)
3.5
Powder coated Mild Steel
FLOOR
97°
2700mm Max.
Wall mount
HEATSTRIP Classic &
Elegance Models
HEATSTRIP Wall Mounting Kit is an ideal way to install units into hard to mount applications
where wall mounting is preferable to direct overhead mounting, applications include heating
over tables, lounges, work stations etc. These kits are suitable for all HEATSTRIP Elegance
& Classic models.
Instructions:
Fix the wall bracket in the desired location using 6 x 8 mm fasten-
ers that will be more than adequate to safely support the bracket
and the HEATSTRIP unit.
When bracket is installed lift the heater into position passing the
power cord through the hole. Locate the heater so the L bracket fits
into the mounting grove located on the back of the HEATSTRIP.
Position the angle piece into the mounting grove on opposite side
of the heater and secure firmly onto the bracket using the 3 screws
provided.