Ensuring you don’t waste energy on heating the outside 
world, the heater is equipped with optional open / 
closed window detection. The heater recognises sudden 
drops in temperature when a window or a door is 
opened and turns the heating off to save energy. When 
the window is closed, the heater will automatically 
detect a temperature rise,  and switch itself back on. 
Once enabled in the setup menu, the open window 
detection is fully automatic and does not require any 
human intervention to be activated.   
 
Setting-up Open Window Detection 
The system has been factory set to default time and 
temperature values. If necessary, all values can be 
adjusted. When the heating is on, open window 
detection sensor will automatically switch the heater off 
when it detects a fall in temperature of 2

°

C in less than 

10 minutes (this temperature can be changed in menu 7 
and time in menu 6). If a temperature rise of 2

°

C in less 

than 30 seconds is detected, the heater will switch itself 
back on (this temperature can be changed in menu 9 
and time in menu 8). 

13. Open Window Detection 

58000390 Iss 01 

1. 

Press and hold TEMP and MODE together for 5 
seconds. 

2. 

The display will enter the setup menu. 

3. 

Use TEMP and MODE to change a value. 

4. 

Use  TIME to scroll between the settings. 

 

01 - temperature calibration 
The temperature reading has been factory calibrated 
but if for any reason it needs adjusting (better accuracy 
required, to suit different position in the room etc.), the 
reading can be recalibrated in 0.5 degrees steps. 

 

02 - change between degrees Celsius or Fahrenheit 

 

03 - set minimum temperature 

 

       (3.5 deg = frost protection) 

 

When this is set, the heater will operate in any mode 
should the room temperature fall below the set 
temperature.

 

 

04 - set maximum temperature 

 

When this is set, the maximum temperature in any mode 
cannot exceed the limit. 
 
05 - open window detection  0 = off, 1 = on 

 

06 - 600 - open window detection time 600 seconds 

 

07 - 2 - temperature drop of 2

°

C in the detection time 

 

08 - 30 - closed window detection time of 30 seconds 

 

09 - 2 -

 

temperature rise of 2

°

C in the detection time 

14. Setup menu 

15. Mounting 

1. 

Mark screw fixing positions on the wall in 
accordance with dimensions shown on the 
diagram.  

2. 

Drill 3 holes for  8mm wall plugs. 

3. 

Insert plugs in to the holes. 

4. 

The two end screws can be now screwed in until 
the heads are approximately 10mm from the wall.  

5. 

Remove the top grille. 

6. 

Hung the unit on the two end screws. 

7. 

Secure the unit with the center screws. 

8. 

Tighten all 3 screws ensuring that the unit is truly 

horizontal. 

9. 

Reattach the top grille. 

 
 

OPTIMUM MOUNTING HEIGHT IS 400mm FROM THE FLOOR.  

NOTE:  

- MINIMUM CLEARANCE FROM THE FLOOR IS 200mm.  

- IF THE HEATER IS MOUNTED AT HIGH LEVEL, THE MINIMUM 

DISTANCE FROM THE CEILING IS 1000mm. 

- THE HEATER MUST NOT BE LOCATED IMMEDIATELY  BELOW 

A FIXED SOCKET OUTLET.  

Summary of Contents for HSCF3000E

Page 1: ...ted to an unsuitable electricity supply or subject to misuse neglect damage or modified or repaired by any person not authorised by us This guarantee is offered to you as an extra benefit and does not affect your legal rights The correct electricity supply voltage is shown on the rating label attached to the appliance Reasonable care has been taken to ensure that this guide is accurate at the time...

Page 2: ...e appliance is covered there is a risk of overheating Cleaning Always disconnect the heater from the mains before cleaning The heater should not require any maintenance but it is strongly advised that it is kept clean An occasional wipe over with a soft cloth is all that should be necessary Do NOT use metal or furniture polish on any part of the heater Do NOT touch the heater with wet hands or in ...

Page 3: ...temperature To amend the set temperature when in Manual mode simply activate the display by pressing any button Press TEMP then use TEMP and MODE to change the temperature Once the temperature is set leave the display to return to the main screen and the settings will be saved 4 BOOST 15 minutes The boost feature increases the room temperature for 15 minutes 1 Use TEMP and MODE to set the temperat...

Page 4: ... set hour use TEMP and MODE to change hour press PROG to set the hour 9 The temperature will be flashing 10 To set temperature use TEMP and MODE to change temperature press PROG to set temperature To add another programme repeat steps 2 10 The HSCF3000E has a 7 day timer with up to 6 programming steps available for each day In the programming you can set a start time and a temperature for each pro...

Page 5: ...rature reading has been factory calibrated but if for any reason it needs adjusting better accuracy required to suit different position in the room etc the reading can be recalibrated in 0 5 degrees steps 02 change between degrees Celsius or Fahrenheit 03 set minimum temperature 3 5 deg frost protection When this is set the heater will operate in any mode should the room temperature fall below the...

Page 6: ...6 15 Mounting 58000390 Iss 01 ...

Page 7: ...Should you need any advice on the use of your new Heatstore product please contact our Helpline Heatstore Unit 12 Access 18 Bristol BS11 8HT Telephone 0117 923 5375 Fax 0117 923 5374 www heatstore co uk 7 58000390 Iss 01 ...

Reviews: