Heatstore Aqua-Power Installation And User Manual Download Page 1

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

IMPORTANT: 

This booklet should be left with the user after 

installation and demonstration 

  

WARNING: 

Under no circumstances should this unit be connected 

to the mains cold water supply

 

Thermostatic Power Shower Unit

 

Installation and User Guide 

Summary of Contents for Aqua-Power

Page 1: ...et should be left with the user after installation and demonstration WARNING Under no circumstances should this unit be connected to the mains cold water supply Thermostatic Power Shower Unit Installa...

Page 2: ...ork supplying the shower unit rise above the level of the bottom of the cold water cistern 6 The Heatstore Aqua Power power shower incorporates a motor that is designed for intermittent use and theref...

Page 3: ...mfortably reached whilst the shower is being used Ensure correct orientation of the shower unit ie mounted as shown in Diagram 1 Choose a flat piece of wall to avoid the possibility of distorting the...

Page 4: ...ter storage cistern and hot water cylinder The shower would be totally unaffected by the other draw off points elsewhere in the system and thus the pressure and temperature will remain more stable The...

Page 5: ...o be on the opposite side of the cistern to the float valve This will prevent air being sucked into the pump chamber 6 It is recommended that isolating valves are fitted between the cold water storage...

Page 6: ...tighten 2 screws in elbow to lock into position 10 With isolating valve connected flush the pipe work through to remove any particles etc before making the final connection to the shower Blockage in t...

Page 7: ...stant rate stop flow of water by switching off the electricity supply Ensure electricity is switched off Remove PCB Commissioning Link and replace with the connector attached to the front cover start...

Page 8: ...re scale for a warmer shower Please allow time for the hot water to reach the shower unit from the storage cylinder Note It is recommended that you test the water temperature with your hand before ste...

Page 9: ...OWER HOSE FOR WEAR AND DAMAGE REPLACE IF NECESSARY OR EVERY TWO YEARS WITH AN APPROVED PART WARNING IN ORDER TO MAINTAIN THE PERFORMANCE OF YOUR SHOWER YOU MUST CLEAN THE SHOWER HANDSET REGULARLY All...

Page 10: ...it and is certainly the person to contact if you have had a problem in the guarantee period The following additional checklist is provided for the benefit of the qualified service person WARNING SWIT...

Page 11: ...e shower deteriorates ie flow reduction occurs then it may be necessary to clean the filters WARNING SWITCH OFF THE ELECTRICITY AT THE LOCAL ISOLATOR BEFORE REMOVING THE COVER TO MAKE CHECKS Remove th...

Page 12: ...11 9DB WEBSITE www heatstore co uk We offer a technical advisory service to installers and other customers with problems in the field RING 0117 923 5375 or E MAIL enquiries heatstore adivision co uk G...