Installation Instructions and Owner’s Manual

Portable Indirect Natural Gas/ Propane Heaters

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

OPERATING INSTRUCTIONS 

AND OWNER’S MANUAL

MODEL#

HSP400ID-G

READ INSTRUCTIONS CAREFULLY:

 YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS. 

Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow 

anyone who has not read these instructions to assemble, light, adjust or operate the heater.

Enerco Group, Inc. reserves the right to make changes at any time, without notice or 
obligation, in colors, specifications, accessories, materials and models.

WARNING:

USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD 

CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT FROM 
THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE AGENCY.  

 

REPLACEMENT PARTS ORDERING INFORMATION:

PURCHASING: 

Accessories may be purchased at any HEATSTAR by Enerco local dealer 

or direct from the factory 

FOR INFORMATION REGARDING SERVICE

Please call Toll-Free 866-447-2194

WWW.HEATSTARBYENERCO.COM

Our office hours are 8:00 AM – 5:00 PM, EST, Monday through Friday.
Please include the model number, date of purchase, and description of problem in all 

communication. 

 

LIMITED WARRANTY

The company warrants this product to be free from imperfections in material or 
workmanship, under normal and proper use in accordance with instructions of The 
Company, for a period of one year from the date of delivery to the buyer. The Company, 
at its option, will repair or replace products returned by the buyer to the factory, 
transportation prepaid within said one year period and found by the Company to have 
imperfections in material or workmanship.
If a part is damaged or missing, call our Technical Support Department at 866-447-2194.

Address any Warranty Claims to the Service Department, Enerco Group, Inc., 4560 W. 

160TH ST., Cleveland, Ohio 44135. Include your name, address, telephone number, serial 
number off heater and include details concerning the claim. Also, supply us with the 

purchase date and the name and address of the dealer from whom you purchased our 
product.

The foregoing is the full extent of the responsibility of the Company. There are no other 
warranties, express or implied. Specifically there is no warranty of fitness for a particular 
purpose and there is no warranty of merchantability. In no event shall the Company be 
liable for delay caused by imperfections, for consequential damages, or for any charges 
of the expense of any nature incurred without its written consent. The cost of repair 
or replacement shall be the exclusive remedy for any breach of warranty. There is no 
warranty against infringement of the like and no implied warranty arising from course 
of dealing or usage of trade. This warranty will not apply to any product which has been 

repaired or altered outside of the factory in any respect which in our judgment affects 
its condition or operation.

Some states do not allow the exclusion or limitation of incidental or consequential 
damages, so the above limitation or exclusion may not apply to you. This Warranty gives 

you specific legal rights, and you may have other rights which vary from state to state.

ENERCO Technical Products, Inc., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 866-447-2194
HEATSTAR is a registered trademarks of ENERCO Technical Products, Inc.
© 2019, ENERCO Technical Products. All rights reserved

Summary of Contents for HSP400ID-G

Page 1: ...ustion and ventilation air must be provided Refer to FRESH AIR AND VENTILATION on page 6 PORTABLE INDUSTRIAL NATURAL GAS PROPANE INDIRECT HEATER OPERATING INSTRUCTIONS AND OWNER S MANUAL MODEL HSP400I...

Page 2: ...AY LEAD TO DEATH USING A PORTABLE HEATER IN AN ENCLOSED AREA CAN PRODUCE DEADLY CARBON MONOXIDE WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAP...

Page 3: ...where it is nebulised and mixed to the combustive air in the combustion chamber A spark triggers combustion while the exhaust fumes are expelled from the chimney A series of sensors constantly checks...

Page 4: ...s at a safe distance from the heater 15 Only use in well ventilated areas Set up a suitable opening in line with current standards with the purpose of introducing fresh air from outdoors 16 Never use...

Page 5: ...n a platform Lift it delicately using hooks and chains Use the holes on the structure to lift the heater 3 Check the heater for possible shipping damage If any damage is found immediately contact the...

Page 6: ...LVES THE GAS CYLINDER MUST ALSO BE CLOSED DISCONNECTED AND STORED IN A SAFE LOCATION ACCORDING TO THE STANDARDS AND REGULATIONS IN FORCE SAFE FROM POSSIBLE RISKS ELECTRICAL CONNECTION WARNING When you...

Page 7: ...e the safety device See Figure 3 FIGURE 3 2 Select the type of gas desired by rotating the knob by 90 degrees 3 Replace the safety device and fasten with the screws removed earlier If required check t...

Page 8: ...g cycle has totally ended When the outlet air temperature drops below 50 C 122 F the fan turns off and the luminous signal of the button turns on to indicate the presence of voltage stand by condition...

Page 9: ...CHAMBER It is recommended to clean the combustion chamber and flue gas duct at least once a year or when required to avoid problems regarding chimney draught and combustion The combustion chamber is...

Page 10: ...r or HEATSTAR customer service Interrupted power cable Contact an authorized technical support center or HEATSTAR customer service Electronics need to be reset or are faulty Reset the heater Contact a...

Page 11: ...r s Manual Portable Indirect Natural Gas Propane Heaters 11 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDED WHILE BURN...

Page 12: ...Heaters NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING PARTS LIST AND DIAGRAM HSP400ID G PARTS LIST AND...

Page 13: ...11 51341 OUTER SHELL 12 51110 T STAT HOUSING 13 51343 CLIP 14 51344 CLIP 15 51096 T STAT AND WIRE 16 51350 NTC SENSOR WIRE 17 51353 BURNER POWER CORD 18 51279 BURNER 19 51280 BURNER HEAD 20 51356 COMP...

Page 14: ...Propane Heaters NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING PARTS LIST AND DIAGRAM HSP400ID G Sub As...

Page 15: ...ROOM T STAT WIRES 6 51114 SAFETY THERMOSTAT 7 51138 TERMINAL BLOCK 8 51374 AUTOMATIC SWITCH 9 51376 BURNER WIRES 10 51377 90 SOCKET 11 51119 THERMOSTAT RESET CAP 12 51379 LIGHT CAP 13 51190 THERMOSTA...

Page 16: ...irect Natural Gas Propane Heaters NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING PARTS LIST AND DIAGRAM...

Page 17: ...ID G P N PART DESCRIPTION 1 51391 COTTER PIN 2 51392 WHEEL WASHER 3 51128 PNEUMATIC WHEEL 4 51091 WHEEL BUSHING 5 51462 LIFTING ARC FOOT 6 51463 LIFTING ARC 7 51090 WHEEL AXLE 8 51086 HANDLE PARTS LIS...

Page 18: ...ral Gas Propane Heaters NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING PARTS LIST AND DIAGRAM HSP400ID...

Page 19: ...amage or personal injury NOTE Not all parts available For questions contact manufacturer PARTS LIST AND DIAGRAM HSP400ID G PARTS LIST AND DIAGRAM P N PART DESCRIPTION 1 51262 BURNER BACK COVER 2 51302...

Page 20: ...uct 16 x 25 F105127 Adapter Ring for Air Recycling System F105128 24 x 25 Duct 24 Clamp for Air Recycling System F105106 Digital Thermostat 33 ft F105108 Remote Analog Thermostat 33 ft PARTS ORDERING...

Page 21: ...EUTRAL 3 GROUND 4 BURNER PHASE 5 BURNER NEUTRAL 6 BURNER GROUND 7 FAN NEUTRAL 8 FAN GROUND 9 FAN PHASE 10 ELECTRONIC BOARD PHASE 1 1 ELECTRONIC BOARD NEUTRAL 12 KEYBOARD GROUND 13 KEYBOARD NEUTRAL 14...

Page 22: ...ed by the buyer to the factory transportation prepaid within said one year period and found by the Company to have imperfections in material or workmanship If a part is damaged or missing call our Tec...