8
Forced-Air Single-Fuel NOMAD Construction Heater
Operating Instructions and Owner’s Manual
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
heated is needed or required. To use this setup you will
need the end diffuser and the 10' specially designed
ducting. To assemble attach one end of the 10' length of
duct to the duct adapter and the other to the end Diffuser.
Then place the end diffuser in the space to be heated.
USING NOMAD HEATER ACCESSORIES
The Nomad line of forced-air heaters is designed to be
used as a stand alone gas fired heating appliance. It is
also designed and certified to be used with a collection
of useful accessories. For information on any additional
accessories that may be available for your model refer
to the list of accessories in this booklet or visit www.
heatstarbyenerco.com.
USING NOMAD HEATERS WITH DUCT & DIFFUSERS
When using this heater to heat a party tent or construction
environment from out side of the space you will need to
employ the help of a few different diffuser attachments.
Direct Diffuser & Duct Adapter
A direct diffuser allows
the user to duct the heat
being produced by the
Nomad heater into a space
needing heat without
having the heater in that
space. To do this you will
need a duct adapter. The
duct adapter attaches to
special connection points
on the heater that match up to the connectors on the
adapter. Align the tabs on the adapter to the holes on
the heater and turn clock wise to lock them in place. Next
you will need the flexible duct transition piece. The duct
transition is a short piece of special silicone lined ducting
that attaches the adapter to the End diffuser. With the
duct adapter attached to the heater, place the transition
duct piece over the outside of the adapter ring and
tighten down the strap. The other end of the Duct is then
attached to the diffuser see Figure 6. The diffuser is an
accessory designed to help direct the air being discharged
from the heater. The air comes out of the diffuser and
spreads out in multiple directions to better fill the space
and heat more evenly. The channel on top of the diffuser
is designed to hold the tent material from falling in front
of the diffuser. The heater can be used without the
diffuser but it is recommended for more effective and
efficient use.
Long Duct & Diffuser
Nomad heaters are also designed to be used with 10'
of flexible duct for when distance from the area to be
FIGURE 6
DIFFUSER
12" X 10' SILICONE LINED
FLEXIBLE HEATING DUCT
F109108
12" X 30" TRANSITION DUCT F109107 12" DUCT ADAPTER F109106
16" DUCT ADAPTER F109116
16" X 30" TRANSITION DUCT F109117
16" X 10' SILICONE LINED
FLEXIBLE HEATING DUCT
F109118
12" UNIVERSAL DIFFUSER
F109105
16" UNIVERSAL DIFFUSER
F109115
FITS HS115SF
FITS HS115SF
FITS HS190SF & HS250SF
FITS HS115SF
FITS HS190SF & HS250SF
FITS HS190SF & HS250SF
DUCT ADAPTER
FIGURE 5
FIGURE 7
FIGURE 8