background image

 6 

Revised 2021 

 

RECOMMENDED MAINTENANCE 

 

MAKE SURE TO TURN OFF THE UNIT, UNPLUG  

AND LET THE MACHINE COOL DOWN BEFORE CLEANING * 

 

NON-STICK COVER & SEAL PLATE 

 

The seal plate can be cleaned, as needed, with a mild spray degreaser. This should be applied to a soft cloth or paper towel 
and then wiped on the plate while cold.  DO NOT WASH DOWN SEAL PLATE OR SPRAY ANY LIQUIDS DIRECTLY 
ONTO THE PLATE. 

 

Replace covers as needed (approximately every 3 months). 

 

Polyamide Film Wrap seals & protects seal plate from moisture  

 

 

CUT OFF ROD 

 Make sure that the unit is turned off and the cut off rod is cool to the touch. 

 

Cover the unit with paper towels to protect it from overspray and debris. 

③ 

Spray the cut-off rod generously with an FDA approved “Degreaser.” 

 

After soaking for a few minutes, lightly scrub the surface of the Cut-off rod with a nylon based product (Scotch-Brite™). 

 

Wipe the surface clean of debris and residue with clean paper towels or cloths and repeat as needed. 

 

CLEANING THE UNIT 

 

The 700ES can be wiped down using mild cleaning detergent and a soft cloth or paper towels.  DO NOT HOSE DOWN OR 
SUBMERGE THE UNIT. 
 

Summary of Contents for 700ES

Page 1: ...Revised 2021 READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING EQUIPMENT OPERATING SERVICE PARTS MANUAL 700ES ENERGY SMART WRAPPER SERIES D...

Page 2: ...2 Revised 2021 TABLE OF CONTENTS Machine Technology Components 3 Preliminary Setup 5 Recommended Maintenance 6 Troubleshooting 7 Heater Control Board Assembly 8 Service Parts Information 9...

Page 3: ...es that the seal plate will consume energy only when there is a demand by the operator ENERGY SMART TECHNOLOGY The Energy Smart Wrapper is an innovative system that incorporates an Instant On seal pla...

Page 4: ...of the unit The GFCI may need to be reset if the wrapper gets wet or other ground faults arise Do not reset the GFCI if visible seal plate damage is present 1 2 3 MACHINE TECHNOLOGY COMPONENTS THERMIS...

Page 5: ...ise and route down and between the two rollers The film goes under the wrapping bridge and rests on top of the black retainer rod The black tension knob can be adjusted for loose rotate counter clockw...

Page 6: ...de Film Wrap seals protects seal plate from moisture CUT OFF ROD Make sure that the unit is turned off and the cut off rod is cool to the touch Cover the unit with paper towels to protect it from over...

Page 7: ...re inside electrical panel Failed cutoff rod With power turned off disconnect both wires of the rod from the terminal block Check resistance between the two wires A good rod will read between 40 500 A...

Page 8: ...8 Revised 2021 HEATER CONTROL BOARD ASSEMBLY NEUTRAL HEATER OUT 24V 0V AUX PRODUCT DETECTION THERMISTOR THERMISTOR 120 VAC...

Page 9: ...ies D Hot Rod Replacement Kit Includes 1 Square Cutoff Rod 1 Rubber Grommet 1 Screw 8 32 x 3 8 Long 1 Retainer Cutoff Rod 1 2 sq Vinyl Replacement Kit Includes 1 Film Retainer 2 Black Plastic Shaft Re...

Page 10: ...0 070 Circuit Board Mounting Kit Includes 4 Plastic Clip Stand Offs 3 1 1875 055 Terminal Block 4 1 1815 030 1A Circuit Breaker 5 1 1815 031 20A Circuit Breaker 6 1 1872 123 GFCI Blank Outlet 20A 125V...

Reviews: