Heatrae Sadia B3 M Fitting Instructions And User Manual Download Page 5

5

3.0 INSTALLATION 

Warning: this appliance must be earthed. It is suitable for a.c. supply only. 
Electrical installation must be carried out by a competent electrician and be in 
accordance with the latest IEE wiring regulations
Warning: Do not connect any pressure-relief device to the vent pipe of this 
water heater.
Warning: The outlet acts as a vent and must only be connected to a fitting 
recommended by the manufacturer. It must not be connected to a tap.

1.  National Wiring rules may contain restrictions concerning the installation of 

these units in bathrooms.

2.  The unit should be vertically wall mounted using the wall bracket and levelling 

feet supplied (see Section 3.1 INSTALLATION - WALL MOUNTING). The inlet 
and outlet water connections must always be on the bottom of the unit.

3.  Enough space should be left below and at the top above the unit for pipe 

connections. Refer to Diagram 1 and the Dimensions Table to determine a 
suitable position for the heater.

4.  NOTE: Ensure that the wall can support the full weight of the unit (see 

TECHNICAL SPECIFICATIONS) and that there are no hidden services (electricity, 
gas, or water) below the surface of the wall.

5.  DO NOT install where the unit may freeze.
6.  Refer to the section IMPORTANT INSTALLATION POINTS to determine which 

valves and accessories are required.

7.  The water connections are 15mm diameter copper tubes suitable for compression 

fittings. Do not use solder joints as this will damage the heater.

8.  The INLET is marked BLUE, the  OUTLET is marked RED. It is recommended that 

a WRAS Listed isolating valve be fitted on the cold water supply to the heater.

9.  Plumbers Paste must not be used as it can impair the operation of components.

Direct

Supplier’s name or trade mark
Supplier’s model identifier

B3

C3

Storage volume V in litres

30.0

50.0

Mixed water at 40 °C V40 in litres

50

77

The declared load profile

S

M

The water heating energy efficiency class of the model

D

D

The water heating energy efficiency in %

30.6

34.5

The annual electricity consumption in kWh 

603

1489

Daily fuel consumption Q fuel in kWh 

2.940

7.060

The thermostat temperature settings of the water heater, 
as placed on the market by the supplier 
Specific precautions that shall be taken when the water 
heater is assembled, installed or maintained and disposed 
of at end of life

B3M/C3M 

60°C

See section 2 to 6

Table

Technical parameters in accordance with European Commision 

regulations 814/2013 and 812/2013

Summary of Contents for B3 M

Page 1: ...Fitting Instructions and User Guide B3 C3 M RANGE...

Page 2: ...3 0 INSTALLATION 5 4 0 COMMISSIONING 11 5 0 EXPLANATION TO USER 12 6 0 MAINTENANCE 14 7 0 FAULT FINDING 15 8 0 SPARE PARTS 16 9 0 ACCESSORIES 16 10 0 GUARANTEE 17 11 0 ENVIRONMENTAL INFORMATION 17 12...

Page 3: ...f they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user mainten...

Page 4: ...be arranged to discharge into the cold water feed cistern The vent pipe must have a minimum bore of 19mm More than one conventional tap can be supplied 1 2 PACK CONTENTS Before commencing installation...

Page 5: ...water below the surface of the wall 5 DO NOT install where the unit may freeze 6 Refer to the section IMPORTANT INSTALLATION POINTS to determine which valves and accessories are required 7 The water c...

Page 6: ...e pads of the Levelling Feet and affix them to the lower back of the unit in the approximate positions shown on Figure 2 4 Hang the unit on the wall mounting bracket ensuring the location bolt locates...

Page 7: ...ure of 0 4 bar 4 metres head A drain cock should be incorporated in the supply to facilitate draining the heater for maintenance 5 The inlet tap should be fitted to the INLET pipe of the heater The in...

Page 8: ...nt pipe of this water heater 5 The cold water supply must be from a cold water feed cistern complying with Byelaw 30 The maximum head pressure must not exceed 20 metres 6 It is recomended that an WRC...

Page 9: ...9 FIGURE 04 TYPICAL CISTERN FED INSTALLATION DRAIN COCK VENT PIPE CISTERN TANK ISOLATING VALVE B3 C3 M HEATER...

Page 10: ...with a 1 0m 3 core 1 5mm2 flexible cable The electicity supply should be fused 13 Amp for a 3kW model and be via a double pole isolating switch with a contact separation of at least 3mm in both poles...

Page 11: ...or 4 2 4 below Always switch off the electrical supply before removing the terminal cover 3 Setting the mid range position Rotate the thermostat knob to the mid position Remove the terminal cover by...

Page 12: ...not the system pipework 4 Show how the thermostat can be locked in either the mid range or hot position and recommend that this procedure is carried out by a qualified electrician 5 Show that the ind...

Page 13: ...Sadia The outlet of the tap must not be restricted or blocked in any way In an Open Outlet installation it is normal for the hot outlet to drip during heating This is due to the expansion of water as...

Page 14: ...ning the drain cock in the inlet pipework 3 Remove the terminal cover by using a large flat bladed screwdriver to depress the 4 snap lugs located in the 4 rectangular depressions on the bottom cover 4...

Page 15: ...lace if necessary Element fault Check element for circuit continuity and insulation resistance If faulty replace No water flow General Cold water supply not turned on Check mains water supply is on Bl...

Page 16: ...5 607 996 Spout and adaptor 95 604 212 9 0 ACCESSORIES The heater can be used to supply only one outlet when used in an open outlet installation More outlets can be supplied in a cystern fed installat...

Page 17: ...ot guaranteed against excessive scale build up This guarantee does not affect the statutory rights of the consumer 11 0 ENVIRONMENTAL INFORMATION The Waste Electrical and Electronic Equipment Producer...

Page 18: ...__ Installer Electrical ________________________________________ Contact Details ____________________________________________ Competency Scheme ID Number _________________________ Comments ___________...

Page 19: ...___________ ________________________________________________ ________________________________________________ Service Date _______________________________________________ Engineer ____________________...

Page 20: ...Newey Eyre Unit 3 5 Wassage Way Hampton Lovett Ind Estate Droitwich Worcestershire WR9 0NX Tel 01905 791500 Fax 01905 791501 UK Spares Ltd Unit 1155 Aztec West Almondsbury Bristol BS32 4TF Tel 01454...

Reviews: