Heatrae Sadia Accolade Installation And User Instructions Manual Download Page 2

2

Figure 1 Internal components

Figure 2 Wiring diagram

Fixing Lugs

Thermal cutout

Printed Circuit
Board (PCB)

Front cover

Heat
exchanger

Water
control valve

Outlet pipe

Pressure relief device

Removable
bottom
section

Inlet spigot

Fixing lug

Alignment
post

Drain slot

Solenoid
valve

L & N
terminal
block

Earth
terminal
block

Back plate

N L

red

green/yellow

black

Cut

Out

Terminal

block

red

Inner

container

brown

white

black

red

white

red

red

red

red

brown

LH

RH

white

Pressure switches

PCB

Solenoid

black

19

REMEDY

A. Switch off shower and isolating switch.  Renew fuse or

reset mcb.  If they operate a second time, contact a
qualified electrician.

B. Follow the same procedure as above.  If this has

happened with a ‘split load’ consumer unit on initial
installation, check that the neutral core of the shower
feed cable is connected to the ‘protected’ neutral bar
of the unit.

A. Descale handset as described in 8.5.  Reset the timer

as described in 5.56.

POSSIBLE CAUSE

A. Cartridge fuse or

miniature circuit
breaker (mcb) has
operated in your
fusebox (or
consumer unit) or
switch fuse.

B. Residual current

device (rcd) (or
earth leakage
circuit breaker)
has operated.

A. Handset needs

descaling.

SYMPTOM

6. “Low Flow”

indicator not lit.
Isolating switch
“On” but its
neon not lit

 

.

7. ‘Inspect Handset’

warning light
flashes.

Where a fault cannot be corrected by
either yourself or your installer, contact our
Service Department, (address and phone
number below), who will try to help over
the phone.  If necessary, they can arrange
a visit by one of our service engineers.
We find that the vast majority of problems
can be solved by reference to these fitting
instructions or by discussion over the
phone.  In the event that our engineer is
called and finds that the fault is caused by
faulty installation or usage, or lack of
reasonable maintenance, a call-out
charge will be made.

Summary of Contents for Accolade

Page 1: ...0 Chantry Gate Business Centre Springfield Road Hayes Middlesex Tel 020 8573 0574 Parts Center Network 65 Business Park Bentley Wood Way Burnley Lancashire BB11 5ST Tel 01282 834403 www partscenter co...

Page 2: ...ected to the protected neutral bar of the unit A Descale handset as described in 8 5 Reset the timer as described in 5 56 POSSIBLE CAUSE A Cartridge fuse or miniature circuit breaker mcb has operated...

Page 3: ...d be careful not to turn water control knob too far anticlockwise Reset as in A A Increase the flow by turning the water control knob anticlockwise Clean the handset and sprayplate B Ensure that your...

Page 4: ...ion 2 11 The shower heater outlet hose and handset act as a vent They must not be blocked obstructed or have connected to them any fitting not approved by the manufacturers The use of unapproved acces...

Page 5: ...not be covered by the guarantee WARNING If you suspect your shower is frozen DO NOT SWITCH ON If you have switched on SWITCH OFF IMMEDIATELY Refer to Fault Finding p17 2 14 Do not leave the infirm di...

Page 6: ...If the handset can reach to within 25mm 1 of the spillover level of the bath shower tray wash basin WC or bidet then to prevent the possibility of back siphonage of used water Water Regulations Guide...

Page 7: ...by frost and the inner container with integral heating element is not guaranteed against excessive scale build up This guarantee in no way affects the statutory rights of the consumer The policy of He...

Page 8: ...water to be flushed from the can When flow stops turn off the isolating switch USER PROTECT SYSTEM 5 50 The User Protect system is intended to prevent showering temperatures reaching harmful levels To...

Page 9: ...e Continue to turn the water control knob clockwise the flow will reduce and the LOW FLOW light will flash Turn the water control knob anticlockwise until the LOW FLOW light goes OFF and the temperatu...

Page 10: ...have been made 5 19 Carry out any cutting with pipe cutters in preference to a hacksaw to minimise swarf Use 15mm compression fittings preferably with copper compression rings olives for the connecti...

Reviews: