background image

USER MANUAL: 

How to use

 heater controller H+h E

                                                                                 

1

 

+

 

Max heating temperature

Selection for 1/2/3 hours

Off selection

TURBO mode activation

3

sec

+

TURBO mode activation –

 max heating temperature 

Hold button for 3 seconds

2

TIMER mode activation

3

+

1. Select temperature
2. Hold button “

” for 2 seconds

symbol will appear on the display

t1

3. Using +/- buttons set the desired number of heater 

work hours (

1-9

)

After the programmed time expires, the heater will 

turn off

Run the controller

Hold upper button 

for 3 seconds

 

Switch off the controller

Hold lower button 

for 5 seconds

3

sec

5

sec

DO NOT DISCONNECT!

controller from heating element, when connected to the power supply

ECONOMY

10

˚

C - 65

˚

C

Select temperature 

40

˚

C

Standard heating 

temperature

[ 7 ]

Summary of Contents for Home Plus Economy

Page 1: ...USER MANUAL HEATER CONTROLLER H h HEATER CONTROLLER HORIZONTAL ECONOMY INSTALLATION MANUAL USER MANUAL HEATER CONTROLLER H h E H HE_EN0920 HEATER CONTROLLER HORIZONTAL VERTICAL...

Page 2: ...tention should be paid to children to preclude playing with the appliance by them Exclamation mark on triangular field signals information important for the user CAUTION electric shock hazard lightnin...

Page 3: ...ru dla 1 2 3 godzin grzania Wy czanie trybu TURBO Aktywacja trybu TURBO Tryb TURBO aktywacja maksymalna temperatura grzania Przytrzymaj przycisk przez 3 sekundy 3 Aktywacja trybu TIMER 4 ECONOMY 3 sek...

Page 4: ...apply the heating element spread the Loctite glue included in the set on the middle of the thread circumference 6A 230V 6B 230V Live Earth Neutral For the heater permanently connected hard wire there...

Page 5: ...www homeplus system com 1 10 C 65 C Wyb r indywidualnej temperatury 2 Uruchamianie grza ki Przytrzymaj wci ni ty g rny przycisk przez 3 sekundy Wy czanie grza ki Przytrzymaj wci ni ty dolny przycisk p...

Page 6: ...from the supply mains in 2 poles with contact separation of at least 3 mm 9B 230 V Connection with a coiled cable and a plug 4 230V CAUTION Do not disconnect heater controller when the system is power...

Page 7: ...old button for 2 seconds symbol will appear on the display t1 3 Using buttons set the desired number of heater work hours 1 9 After the programmed time expires the heater will turn off Run the control...

Page 8: ...Mnik w 322 32 084 Morawica Polska Tel fax 48 12 656 44 91 www heatpol pl www homeplus system com...

Reviews: