Updated: 07/10/12

Ash Removal

 

1) When removing ashes, always turn off the combustion air blowers.

 

2) Open the outer door, which releases the auger tube cover plate.

 

3) insert the ash auger and remove the ashes.

Supply Line and Return Line Threaded Connectors

There are two 1.5” Supply line and two 1.5” Return line threaded connectors (female nPT) located at the back 

of the Model 600 CSS. A brass nipple should be used to connect any fittings to the threaded spuds. Refer to 

the “Supply Line and Return Line Threaded Connectors” section in the Operators and maintenance manual.

Low Water Cutoff

Principles

The low water Cutoff (located above the flue) shuts down power to the fans 

when the water in the furnace is low. 

The only way to restore power to the fans is to fill the furnace with water. 

Do not fill a warm furnace with cold water.

Outer Door

Operation 

The outer door on the firebox is hinged and latched separately from the internal fire 

door.

 

The door is hinged and opens to the right of the furnace. As the door opens it 

releases the A.R.D. auger tube cover plate, which allows air to enter the firebox before 

the fire door is opened, reducing the risk of a flashback. It is strongly recommended that 

a post is installed to the outside corner of the opened door to fasten the back and front 

external doors secure while in the open position. This reduces the risk of injury caused 

by the sudden movement of either large door (see drawing supplied).

Summary of Contents for 600 CSS

Page 1: ...ifications 3 Bladder 5 Fire Door 6 Air Supply 8 Anti Rollout Device and Ash Auger Tube 10 Supply Line and Return Line Threaded Connectors 11 Low Water Cutoff 11 Outer Door 11 Site Preparation Specific...

Page 2: ...AND MAINTENANCE MANUAL AND THIS SUPPLEMENT BEFORE OPERATING YOUR HEATMOR STAINLESS STEEL OUTDOOR FURNACE MODEL 600 CSS NOTE NEVER START A FIRE INSIDE THE FIREBOX UNTIL THE WATER JACKET IS FULL OF WATE...

Page 3: ...rebox height Inches 48 Volume of firebox Cu Ft 63 Firebox Door Size Inches 30 x 36 Flue transfer area Sq Ft 25 BTU S maximum 600 000 Water Jacket Steel Gauge Stainless 7 Firebox Steel Gauge Stainless...

Page 4: ...unit Limited LIFETIME Warranty Approvals Test Standards UL 2523 2009 CSA B366 1 11 Hookup Location Back Total Heat Extraction area sq ft 109 Type of Fuel WOOD ONLY Electrical Supply 1 Phase 115 Volts...

Page 5: ...rature is less than 100 F 38 C 1 Turn off the bladder gate valve located behind the top front access door 2 Remove the bladder cover plate by loosening the thumbnut and pulling out the plate 3 Loosen...

Page 6: ...assistance Opening the Fire Door It is important to always stand behind the fire door when opening it Open the door just slightly to allow air to the firebox This clears the firebox of smoke that may...

Page 7: ...tighter seal between the door seal gasket and doorframe Once the door has been adjusted to the correct depth the inner and outer nuts should once again be tightened against each other to hold the doo...

Page 8: ...ion where the furnace is overfilled with wood An over filled furnace will smoke more than one that has been properly filled with wood A properly filled furnace will have less problems with debris in t...

Page 9: ...required for optimal efficiency For example small pieces of wood high surface area with low moisture content requires a small amount of primary air and a large amount of secondary air If the opposite...

Page 10: ...r opening practices the risk of a flash back is greatly reduced Operation The A R D opens and closes automatically with the operation of the outer door Maintenance Result Ensure ash shavings or small...

Page 11: ...cated above the flue shuts down power to the fans when the water in the furnace is low The only way to restore power to the fans is to fill the furnace with water Do not fill a warm furnace with cold...

Page 12: ...12 Updated 07 10 12 Site Preparation Specifications Model 600...

Page 13: ...Pad Specifications Model 600 Notes 1 Pad sizes are shed base dimensions plus 3 inches in width and 2 inches in length 2 Pad thickness must be at least 4 inches but not more than 12 inches 3 All measur...