Optional Features Explained
THE FOLLOWING SETTINGS ARE OPTIONAL AND IN MOST CASES
NEED NOT BE ADJUSTED
Feature 01 – Temperature Format:
This function allows you to select between °C and °F.
Feature 02 – Switching Differential:
This function allows you to increase the switching
differential of the thermostat. The default is 1°C which means that with a set temperature
of 20°C, the thermostat will switch the heating on at 19°C and off at 20°C.
With a 2°C differential, the heating will switch on at 18°C and off at 20°C.
Feature 03 – Frost Protect:
You can set whether the thermostat will maintain the frost
temperature when the thermostat display is turned off. As a default, this is enabled
Feature 04 – Output Delay:
To prevent rapid switching, an output delay can be entered.
This can be set from 00 - 15 minutes. The default is 00 which means there is no delay.
Feature 05 – Temperature Up/Down Limit:
This function allows you to limit the use of the
up and down keys. This limit is also applicable when the thermostat is locked and so allows
you to give others limited control over the heating system.
Feature 06 – Sensor Selection:
On this thermostat, you can select which sensor should
be used. You can select between air temperature only, floor temperature, or both. When
you enable both sensors, the floor sensor is used as a floor limiting sensor and is designed
to prevent the floor from overheating.
Note: Built in air sensor only MUST NOT be used to control electric underfloor heating. Floor sensor
only or built in air & floor sensor together must be used.
21
Slimline
Series
Summary of Contents for Slimline Series
Page 1: ...Model Slimline E V3 ...
Page 2: ...1 Slimline Series Model Slimline E V3 ...
Page 7: ...1 2 3 4 Model Slimline E V3 6 ...
Page 9: ...Mode 1 Thermostat Model Slimline E V3 8 ...
Page 10: ...1 2 3 4 5 13 6 7 8 9 10 11 12 9 Slimline Series ...
Page 29: ...7 1 2 3 5 6 4 8 Model Slimline E V3 28 ...
Page 40: ... Model Manual REF 39 Notes 39 Slimline Series ...
Page 41: ... Notes Model Slimline E V3 ...