Optional Features Explained
Feature 01 - Temperature Format:
This function allows you to select between °C and °F.
Feature 02 – Switching Differential:
This function allows you to increase the switching
differential of the thermostat. The default is 1°C which means that with a set temperature
of 20°C, the thermostat will switch the heating on at 19°C and off at 20°C.
With a 2°C differential, the heating will switch on at 18°C and off at 20°C.
Feature 03 – Frost Protect:
You can set whether the thermostat will maintain the frost
temperature when the thermostat display is turned off. As a default, this is enabled.
Feature 04 – Output Delay:
To prevent rapid switching, and output delay can be entered.
This can be set from 00 - 15 minutes. The default is 00 which means there is no delay.
Feature 05 – Temperature Up/Down Limit:
This function allows you to limit the use of the
up and down keys. This limit is also applicable when the thermostat is locked and so
allows you to give others limited control over the heating system.
Feature 06 – Air Sensor Selection:
On this thermostat, you can select which sensor should
be used - built in sensor or remote air sensor.