Heatmiser DS1-EL Manual Download Page 2

In normal mode, the display shows the actual room temperature. To change the set point, 
rotate the dial until the digital LCD displays the new set temperature.

Setting The Temperature

Display Icons

The Heatmiser DS1-EL has a lock facility.  To lock the thermostat, press and hold down the 
dial for 10 seconds.  You will see a lock symbol appear.  To unlock, repeat the steps above.

Heating ON

Keypad Locked

The Heatmiser DS1-EL offers 1, 2 and 3°C switching differential. 
With a 1°C switching differential the heating will switch on 1°C below the set 
temperature and will turn off when the set temperature is reached.
A 2°C will turn the heating on 2°C below the set temperature.
3°C will switch the heating on 3°C below the set temperature.
To set the differential, set the DIP switches according to the table below. 

This setting is only required when the sensor option is set to Air and Floor mode. 
The setting is used to protect the floor surface from overheating. 
The floor temperature limit can be set to 20, 28 or 40°C.
To set the required floor limit temperature, set the DIP switches according to the table. 

The thermostat has three modes of operation.  Select the desired mode, 
and set the DIP switches according to the table. 
The DIP switches can be accessed from the back of thermostat.
Air Sensor: Uses the built in air sensor only.
Air Sensor & Floor Limiting Sensor: Uses the built in air sensor but also uses the 
remote floor sensor to ensure the floor temperature doesn’t overheat.
Floor Sensor: Uses the remote floor sensor only.

Lock Facility

Switching Differential

Floor Temperature Limit

Sensor Option

1

2

1 °C Switching

2 °C Switching

3 °C Switching

20°C
28°C
40°C

Air Sensor

Air & Floor

Floor Sensor

1

2

3

1

2

3

1

2

3

Switch 1 & 2 OFF

Switch 1 ON and Switch 2 OFF

Switch 1 OFF and Switch 2 ON

Switch 5 & 6 OFF

Switch 5 ON and Switch 6 OFF

Switch 5 OFF and Switch 6 ON

Switch 3 & 4 OFF

Switch 3 ON and Switch 4 OFF

Switch 3 OFF and Switch 4 ON

2

2

2

3

3

3

1

1

1

Should the floor temperature be achieved (even if the desired room temperature has 
not) the heating will turn off. The Heat Active Icon will flash in this case.