Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4236I-NVR, NDV4842I-B Owner’s Manual • 2382-981 Rev. N • 5/22
Decorative Barrier Fronts
Frequency:
Annually
By:
Homeowner
Tools needed
: Protective gloves, stable work surface
• Assess condition of screen and replace as necessary.
• Inspect for scratches, dents or other damage and repair
as necessary.
•
Check that air intake and discharge areas are not
blocked.
•
Vacuum and dust surfaces.
Remote Control (Optional)
Frequency:
Seasonally
By:
Homeowner
Tools needed:
Replacement batteries and remote con-
trol instructions.
• Locate remote control transmitter and receiver.
• Verify operation of remote. Refer to remote control
operation instructions for proper calibration and setup
procedure.
• Place batteries as needed in remote transmitters and
battery-powered receivers.
• Place remote control out of reach of children.
If not using your fireplace for an extended period of time
(summer months, vacations/trips, etc), to prevent unin-
tended operation:
• Remove batteries from remote controls.
• Unplug 3 volt adapter plug on IPI models.
• Clean glass with a non-abrasive, non-ammonia based,
commercially available gas fireplace glass cleaner
.
- Light deposits: Use a soft cloth with soap and water
- Heavy deposits: Use commercial fireplace glass
cleaner (consult with your dealer)
• Carefully set fixed glass assembly in place on fireplace.
Hold glass in place with one hand and secure all glass
latches with the other hand.
• Inspect and operate all glass latches to ensure they
move freely and no obstructions are present.
• Reinstall decorative barrier front.
Venting and Termination Cap
Frequency:
Seasonally
By:
Homeowner
Tools needed:
Protective gloves and safety glasses.
• Inspect exposed venting and termination cap for block
-
age or obstruction such as plants, bird nests, leaves,
snow, debris, etc.
• Verify termination cap clearance to subsequent construc-
tion (building additions, decks, fences, or sheds).
• Inspect for corrosion or separation.
• Verify caulking and sealing of vent components and
termination cap remains intact.
• Inspect draft shield to verify it is not damaged or missing.