22
30803 Rev X
08/04
CALIBER DIRECT VENT INSTALLATION INSTRUCTIONS
5. Wiring
a.
Intermittent Pilot Ignition
1)
This appliance requires a 110VAC supply to the appliance junction box for operation. A wiring diagram is
shown in Figure 49.
2)
This appliance is equipped with an intermittent pilot control valve which operates on a 3V system.
3)
This appliance is supplied with a battery pack and a 3VAC transformer, which requires the installation of the
supplied junction box. We highly recommend that the junction box be installed at this time to avoid
reconstruction.
The battery pack is supplied in the installation assembly. The battery pack should be connected as shown
in Figure 49 and placed on the bottom pan of the applience.
The battery pack requires two D cell batteries (not included). Batteries cannot be placed in the battery pack
while using the 3 VAC transformer. Conversely, the transformer must be unplugged if the batter pack is
used.
Note:
This appliance must be electrically wired and
grounded in accordance with local codes or, in the ab-
sence of local codes, with
National Electric Code ANSI/
NFPA 70-latest edition
or the
Canadian Electric Code,
CSA C22.1
.
Figure 49 - Intermittent Pilot Ignition Wiring Diagram
CAUTION:
Battery polarity must be cor-
rect or control module damage
will occur.
Note:
Optional Accessories Requirements: Wiring for optional accessories should be done now to avoid reconstruction.