C. Install the Ceiling Firestop
$ FHLOLQJ ¿UHVWRS
MUST
EH XVHG EHWZHHQ
ÀRRUVDQGDWWLFV
'933LSHRQO\)UDPHDQRSHQLQJLQ
E\LQPPE\PPZKHQHYHU
WKH YHQW SHQHWUDWHV D FHLOLQJÀRRU VHH
)LJXUH
6/33LSHRQO\)UDPHDQRSHQLQJLQ
E\LQPP[PPZKHQHYHUWKH
YHQWSHQHWUDWHVDFHLOLQJÀRRUVHH)LJXUH
)UDPHWKHDUHDZLWKWKHVDPHVL]HGOXPEHU
DVXVHGLQFHLOLQJÀRRUMRLVW
7KHFHLOLQJ¿UHVWRSPD\EHLQVWDOOHGDERYH
RU EHORZ WKH FHLOLQJ MRLVWV ZKHQ LQVWDOOHG
ZLWK D DWWLF LQVXODWLRQ VKLHOG ,W PXVW EH
XQGHU MRLVWV EHWZHHQ ÀRRUV WKDW DUH QRW
LQVXODWHG5HIHUWR)LJXUH
6HFXUHZLWKWKUHHIDVWHQHUVRQHDFKVLGH
:$51,1*5LVNRI)LUH'2127
pack insu-
lation around the vent. Insulation must be kept
back from the pipe to prevent overheating.
Figure 8.3 Installing Ceiling Firestop
Figure 8.4 Installing the Attic Shield
3 FASTENERS
PER SIDE
INSTALL ATTIC INSULATION SHIELDS
BEFORE OR AFTER INSTALLATION OF VENT SYSTEM
CEILING FIRESTOP
INSTALLED BELOW CEILING
CEILING FIRESTOP
INSTALLED ABOVE CEILING
ATTIC ABOVE
A
PIPE
DVP
SLP
A
10 in. (254 mm)
9 in. (229 mm)
A