19
August 23, 2019
7074-801C
HEATILATOR ECO CHOICE CAB50
Figure 19.1
Clean-Out Cover
14. Preparing Firebox for Non-Burn Season
• Frequency:
Yearly
• By:
Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off.
b.
Remove all ash from the firebox and
vacuum thoroughly.
c.
Paint all exposed steel, including cast-iron.
—
Purchase paint from your local dealer.
— Must use a high-temperature paint made
specifically for heating appliances.
12. Cleaning Convection Blower - Requires No
Lubrication
• Frequency:
Yearly or more frequently depending on
Dust/Dirt build-up
• By:
Homeowner or Qualified Service Technician
a. Be sure the appliance is allowed to cool and has
been unplugged.
b.
Follow the directions on page 21 for direct access
to the convection blower.
c. Sweep or vacuum out any build-up. Use a brush or
compressed air to loosen dirt if needed.
13. Cleaning the Top Vent Adapter
• Frequency:
Yearly or more frequently depending on
ash build-up
• By:
Homeowner
a. The appliance must be in complete shutdown
and the exhaust blower should be off. Allow the
appliance to completely cool down.
b.
Open the clean-out cover
(Figure 19.1)
.
c. Sweep or vacuum out any ash build-up.