24
December 9, 2019
7059-801D
HEATILATOR ECO CHOICE PS50
A. Convection Blower Replacement
1. Turn down the thermostat, let appliance completely
cool and then unplug appliance before servicing.
2.
The convection blower is located on the floor at the
rear of the appliance.
3.
Lift the hopper lid up until it locks into place.
4.
Loosen the 4 screws on the upper back panel and the
2 screws on the lower back panel, using a #2 Phillip
Head screwdriver, a 3/8 inch wrench or a 3/8 Inch
socket. You do not need to remove them
(Figure 24.1)
.
5.
Remove the left upper and lower side panels by lifting
up and out. The hooks on the panels will slide out of
the slots on the appliance
(Figure 24.2)
.
6. Release blower wires from the nylon wire retainer if
applicable. This appliance has 1 black and 1 white wire
coming from the blower.
7. Remove the wing bolt and move the blower and hold-
down bracket toward the back of the appliance to
release the locating tab
(Figure 24.3)
. Pull the blower
out from under the convection plenum. Slide the blower
out of the appliance. Disconnect the wires from the
spade connectors at this time
(Figure 24.4)
.
8. Return wires to nylon wire retainer. Make sure wires
do not contact any moving parts or touch any surfaces
that may become hot
(Figure 24.4)
.
5
Service Parts Replacement
Loosen Screws,
Do Not Remove
Figure 24.1
Figure 24.2
Figure 24.3
Figure 24.4
Nylon Wire Retainer
Nylon Wire Retainer
Wing Screw
Locating Tab
Hold Down Bracket
Spade
Connectors
Upper Left
Panel
Lower Left Panel
Lift Up and Out of Slots