B. Glass Speci
fi
cations (Tempered)
Hearth & Home Technologies appliances manufactured
with tempered glass may be installed in hazardous lo-
cations such as bathtub enclosures as de
fi
ned by the
Consumer Product Safety Commission (CPSC). The
tempered glass has been tested and certi
fi
ed to the re-
quirements of
ANSI Z97.1
and
CPSC 16 CFR 1202
(Safety Glazing Certi
fi
cation Council
SGCC# 1595
and
1597
. Architectural Testing, Inc. Reports
02-31919.01
and
02-31917.01
).
This statement is in compliance with
CPSC 16 CFR Sec-
tion 1201.5
“Certi
fi
cation and labeling requirements”
which refers to
15
U.S. Code
(USC) 2063
stating “…Such
certi
fi
cate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered.”
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
C. BTU Speci
fi
cations
A. Appliance Certi
fi
cation
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
NOTICE:
This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
2
2
Product Speci
fi
c Information
This product is listed to ANSI standards for “Vented Gas
Fireplace Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles”, and “Gas Fired Appliances for
Use at High Altitudes”.
MODELS:
CD4236-MOD, CD4842-MOD
LABORATORY:
Underwriters Laboratories, Inc. (UL)
TYPE:
Direct Vented Gas Fireplace
STANDARD:
ANSI Z21.50-2014 • CSA 2.22-2014
Models
(U.S. or Canada)
Maximum
Input
BTU/h
Minimum
Input
BTU/h
Ori
fi
ce
Size
(DMS)
CD4236-MOD
(NG)
US
(0-2000 FT)
28,000
19,000
40
CANADA
(2000-4500 FT)
25,200
17,100
41
CD4236-MOD
(LP)
US
(0-2000 FT)
20,000
14,000
55
CANADA
(2000-4500 FT)
18,000
12,000
56
CD4842-MOD
(NG)
US
(0-2000 FT)
32,000
22,000
35
CANADA
(2000-4500 FT)
28,800
19,800
36
CD4842-MOD
(LP)
US
(0-2000 FT)
22,000
15,000
54
CANADA
(2000-4500 FT)
20,000
14,000
55
Installation and service of this
appliance should be performed by
quali
fi
ed personnel. Hearth & Home
Technologies recommends HHT
Factory Trained or NFI certified
professionals.