B. Glass Speci

fi

 cations (Tempered)

Hearth & Home Technologies appliances manufactured 
with tempered glass may be installed in hazardous lo-
cations such as bathtub enclosures as de

fi

 ned by the 

Consumer Product Safety Commission (CPSC). The 
tempered glass has been tested and certi

fi

 ed to the re-

quirements of 

ANSI Z97.1

 and 

CPSC 16 CFR 1202 

(Safety Glazing Certi

fi

 cation  Council 

SGCC# 1595

 and 

1597

. Architectural Testing, Inc. Reports 

02-31919.01

 

and 

02-31917.01

).

This statement is in compliance with 

CPSC 16 CFR Sec-

tion 1201.5 

“Certi

fi

 cation and labeling requirements” 

which refers to 

15 

U.S. Code 

(USC) 2063 

stating “…Such 

certi

fi

 cate shall accompany the product or shall otherwise 

be furnished to any distributor or retailer to whom the 
product is delivered.”
Some local building codes require the use of tempered 
glass with permanent marking in such locations. Glass 
meeting this requirement is available from the factory. 
Please contact your dealer or distributor to order.

C. BTU Speci

fi

 cations

A. Appliance Certi

fi

 cation

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.  

This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance.  It should not be 
factored as primary heat in residential heating calculations.

NOTICE: 

This installation must conform with local codes. 

In the absence of local codes you must comply with the 
National Fuel Gas Code, ANSI Z223.1-latest edition in 
the U.S.A. and the CAN/CGA B149 Installation Codes in 
Canada.

Product Speci

fi

 c Information 

 

This product is listed to ANSI standards for “Vented Gas 
Fireplace Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and 
Recreational Vehicles”, and “Gas Fired Appliances for 
Use at High Altitudes”.

MODELS: 

CD4236-MOD, CD4842-MOD

LABORATORY: 

Underwriters Laboratories, Inc. (UL)

TYPE: 

Direct Vented Gas Fireplace

STANDARD:

 ANSI Z21.50-2014 • CSA 2.22-2014

Models

(U.S. or Canada)

Maximum

Input 

BTU/h

Minimum

Input 

BTU/h

Ori

fi

 ce

Size 

(DMS)

CD4236-MOD 

(NG)

US

(0-2000 FT)

28,000

19,000

40

CANADA

(2000-4500 FT)

25,200

17,100

41

CD4236-MOD 

(LP)

US

(0-2000 FT)

20,000

14,000

55

CANADA

(2000-4500 FT)

18,000

12,000

56

CD4842-MOD 

(NG)

US

(0-2000 FT)

32,000

22,000

35

CANADA

(2000-4500 FT)

28,800

19,800

36

CD4842-MOD 

(LP)

US

(0-2000 FT)

22,000

15,000

54

CANADA

(2000-4500 FT)

20,000

14,000

55

Installation and service of this 
appliance should be performed by 
quali

fi

 ed personnel. Hearth & Home 

Technologies  recommends HHT 
Factory Trained or NFI certified 
professionals.

Summary of Contents for CD4236-MOD

Page 1: ...DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed fo...

Page 2: ...e De Gaz Gaz N NA ATURAL TURAL GAS GAS MADE MADE IN IN USA USA Minimum Minimum Permissible Permissible Gas Gas Supply Supply for for Purposes Purposes of of Input Input Adjustment Adjustment Approved...

Page 3: ...6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Wall Surface TV Guidelines 8 E Before Lighting Appliance 10 F Lighting Instruc...

Page 4: ...on the date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an indepen...

Page 5: ...RANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes...

Page 6: ...ed as either supplemen tal room heat or as a decorative appliance It should not be factored as primary heat in residential heating calculations NOTICE This installation must conform with local codes I...

Page 7: ...6 volt transformer plug IPI Plus and remove batteries on IPI models 3 3 Important Safety and Operating Information Clear Space WARNING DO NOT place combustible objects in front of the fireplace or bl...

Page 8: ...discussed WARNING Risk of Fire or Explosion Appliance must be set up for compatible gas type This appliance is designed to operate on either natural gas or propane Make sure the appliance is compatibl...

Page 9: ...tures should be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers maximum allowable opera ng temperatures iden ed in...

Page 10: ...e been removed from inside and or underneath the firebox Review proper placement of logs ember material and or other decorative materials Check the wiring Check the air shutter adjustment Ensure that...

Page 11: ...nce Hot while in operation DO NOT touch Keep children clothing furniture gasoline and other liquids having flammable vapors away DO NOT operate the appliance with fixed glass assembly removed cracked...

Page 12: ...long term power source Standard Wall Switch or Factory Installed ON OFF Switch Toggle the switch as you would under normal circumstances Wireless Remote Remote receiver is integrated into the ignition...

Page 13: ...er this 10 second period the flame can be adjusted from HI to LO with the switch 3 The control module has safety feature that automatically shuts down the fireplace after 9 hours of continuous operati...

Page 14: ...off the pilot is also off NOTICE Batteries should not be placed in the battery pack while using the transformer Remove batteries before using the transformer and unplug the transformer before install...

Page 15: ...ill give you many years of trouble free service Contact your dealer to answer questions regarding proper operation trouble shooting and service for your appliance Visit www heati lator com to locate a...

Page 16: ...llowing tasks must be performed by a qualified ser vice technician Gasket Seal and Glass Assembly Inspection Frequency Annually By Qualified Service Technician Tools needed Protective gloves drop clot...

Page 17: ...soot dirt and corrosion Verify orifice size is correct See Service Parts List for proper orifice sizing Verify manifold and inlet pressures Adjust regulator as required Inspect pilot flame pattern and...

Page 18: ...bly by removing the two screws as shown in Figure 4 6 To disengage the burner from the orifice slide the burner to the right and lift it out 6 See Figure 4 7 for valve assembly removal APPEARANCE MAY...

Page 19: ...inishing materials and adhesives used around the appliance Film on the glass This is a normal result of the curing process of the paint and logs Glass should be cleaned within 3 to 4 hours of initial...

Page 20: ...5 in 2 41 mm to 135 in 3 43 mm 2 Pilot won t light there is no noise or spark A No power transformer installed incorrectly or depleted batteries Verify that transformer is installed and plugged into m...

Page 21: ...een module and sense lead is at least 0 14 microamps Verify correct pilot orifice is installed and gas inlet is set to pressure specifi cations Polish flame sensing rod with fine steel wool to remove...

Page 22: ...Zone Gas Kit follow the instruction supplied with the kit for operation See your dealer if you have questions Install approved accessories per instructions included with accessories Contact your deal...

Page 23: ...aler or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 1 Non Combustible Board 2166 136 2 Refractory Bracket Qty 2 req 2241 115 3 Rock Fixture Assembly 2241 040 Y 4 Base Pan Assemb...

Page 24: ...n requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 1 Non Combustible Board 2170 136 2 Refractory Bracket Qty 2 req 2241 115 3 Rock Fixtur...

Page 25: ...ly NG 2090 012 Y Pilot Assembly LP 2090 013 Y 9 3 Pilot Bracket 2241 109 9 4 3 Hole Grommet 2118 420 9 5 Valve Bracket 2118 104 9 6 Flex Ball Valve Assembly 302 320A Y 9 7 Valve NG 2166 302 Y Valve LP...

Page 26: ...ery Pack 2166 323 Y Fuse for battery pack can be sourced locally not a warranty item Specs are 250v 1A fuse 3 4 long Flue Restrictor 385 128 Gasket Assembly 2166 081 Includes Vent Seal Cap Burner Neck...

Page 27: ..._______________________________________________ ________________________________________________________________________________ _______________________________________________________________________...