background image

1.  Select a location on a flat wall with structurally sound wood. The 

wood should be at least 3/4 inch thick to safely secure the fixture.

2.  Loosen  the  two  screws  (A)  securing  the  front  housing  until  the 

screws turn easily. Remove the front housing.

3.  Loosen screw (B) two turns. Slide the reflector up until the keyholes 

clear the screw heads and remove the reflector.

If Mounting Directly to Wall

4.  Knock out slugs at (C) and (D).
5.  Attach cable clamp or flexible conduit to hole (D). Thread the service 

wires thru this hole.

6.  Mount the fixture with two 1/4 inch lag screws that will penetrate 

the wood surface at least 3/4 inch.

Or, if Mounting to a 3-1/2" or 4" Electrical Box

4.  Determine which pair of slots line up with the mounting holes on 

your box, (E) or (F). Knock out the slugs that line up. Knock out 
slug (D).

5.  Thread the service wires thru hole (D).
6.  Mount the fixture to the box with screws of the proper size for your 

box.

Wiring and Final Assembly

7.  Connect the fixture wires to the service wires (

black

 to 

black

 and 

white

 to 

white

). Secure with wire nuts provided.

8.  Secure the service ground wire under the head of the green ground 

screw.

9.  Make sure the wire nuts and wires are inside the circular wiring 

compartment. Reinstall the reflector and tighten screw (B). 

10. Install 

ONLY

 a 35 watt H.P.S. type S76 lamp (provided).

11. Reinstall the front cover.
To test operation during daylight, cover the photocontrol window with 
black tape. Turn on the power. The photocontrol has a time delay (up 
to 2 minutes) before it will respond to light changes. The light will take 
up to ten minutes to reach full brightness. Uncover the photocontrol and 
your unit will operate automatically—on at dusk, off at dawn.

© 2007 HeathCo LLC 

598-1210-01

Ground 

Screw

(A)

Reflector

Photocontrol 

Window

Photocontrol

(C)

(E)

(F)

(C)

(B)

(E)

(F)

(D)

No Service Parts Available for this Product

High Pressure Sodium 

Dusk-To-Dawn Wall Light 

for Canadian Tire

Installation Instructions

READ ALL INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION.

NOTE:  All wiring must be run in accordance with the National Electrical Code (Canadian Electrical Code in Canada) through 

conduit or another acceptable means. Contact a qualified electrician if there is any question as to the suitability of 
the system.

Model SL-5670

 

WARNING: Turn  power  off  at  the  fuse  or  circuit 

breaker.

Lamp in Fixture Contains Mercury. Dispose According 
to Local, State, or Federal Laws.

See your Canadian Tire retailer for warranty information.