background image

2

598-1344-00

teSt anD aDJuStMent

NOTE: Sensor has a 30 second warm up period before 
it  will  detect  motion. When  switching  modes  wait  30 
seconds.

1.  Slide the sensor switch to the TEST position.
2.  Place the RANGE adjustment in the medium position 

(halfway between MIN and MAX position).

 

Least Sensitive 

Most Sensitive

Sensor

Motion

70 ft. 
(21 m)

8 ft. 
(2.4 m)

 

Maximum Range 

Maximum

 

Coverage Angle

MAX

MIN

RANGE

ON-TIME

TEST  1  5   OFF

MINUTES

Bottom of Sensor

Aim Sensor Down for 

Short Coverage

Aim Sensor Higher for 

Long Coverage

Ball Joint

Clamp Screw

adjustment of coverage area

The sensor detects “motion” by the movement of heat 
(body heat) across the coverage area. However, following 
are examples of objects that also produce heat and can 
cause the sensor to false trigger:
•  Pools of Water 

•  Air Conditioners

•  Dryer Vents 

•  Fenced-In Animals

•  Heating Vents 

•  Automobile Traffic

If you suspect that a heat source of this type is falsely 
triggering the sensor, try reducing the RANGE or aiming 
the sensor away from the heat source in question.
Note: The  detector  is  less  sensitive  to  motion  directly 
towards it and more sensitive to across motion. 

Motion

OPeratiOn

Place the sensor switch in the 1 or 5 minute mode for 
normal operation. If the light is not needed, put the switch 
in the OFF position.

Mode:

On-Time

Works:

Day

Night

test

5 Seconds

x

x

auto

1 or 5 Minutes

x

thingS tO reMeMber

•  Periodically clean the solar panel with a soft cloth and 

warm water. Do not hose spray. Keep the collector clear 
of snow and leaves. Make sure trees and other objects 
do not block sunlight from the panel.

•  If not to be used for several weeks, turn the unit OFF. 

Store it with the panel connected and where the panel 
can gather sunlight.

•  Solar collection is only effective in direct sunlight. Every 

hour the light is on requires a minimum of 16 hours of 
sunlight charging. Solar panels collect less than 10% 
of the sun’s energy.

•  Several days of use with overcast skies may discharge 

the battery. Because of the battery protection circuit, the 
light will not work until the battery is fully recharged.

•  This light is supplied with three permanent LED lamps. 

The LED’s are rated to provide a minimum of 40,000 
hours of light output and do not need to be replaced.

3.  Loosen the clamp screw in the sensor ball joint.

4.  Walk through the coverage area noting when the lights 

turn on. Gently move the sensor head up, down, or 
sideways to change the coverage area. Note: Wait 5 
to 10 seconds after light turns off to retest.

5.  Increase RANGE only as needed. A  larger  RANGE 

setting may cause false triggering and reduce battery 
life.

6.  Secure the sensor into position by tightening the clamp 

screw. Do not overtighten the screw.

7.  After dark, loosen the light joint clamps and adjust the 

light to cover desired area. Tighten joint clamps when 
desired area is covered.

180°

Summary of Contents for 7101

Page 1: ...fixture This package includes the following items INSTALLATION For best performance mount the fixture about 8 feet 2 4 m above the ground 1 Mount solar panel base on a solid surface using three tapered screws Adjust the panel to point directly at the noon sun Avoid obstructions such as trees or buildings that may block sun light Allow for enough wire to reach the case Note You will want to re aim ...

Page 2: ...s Day Night Test 5 Seconds x x Auto 1 or 5 Minutes x Things To Remember Periodically clean the solar panel with a soft cloth and warm water Do not hose spray Keep the collector clear of snow and leaves Make sure trees and other objects do not block sunlight from the panel If not to be used for several weeks turn the unit OFF Store it with the panel connected and where the panel can gather sunlight...

Page 3: ...n products previously sold IMPORTANT DONOTreversethebatterywires Dam age to the unit will result Like any lead acid battery this battery must be disposed of properly IMPORTANT Keep sensor switch in the OFF position for three days to allow the battery to fully charge before testing 1 Remove rear battery cover Press in the two catch releases on the cover and remove the cover 2 Removerechargeablebatt...

Page 4: ...ng product to store If you experience a problem follow this guide You may also want to visit our Web site at www hzsupport com If the problem persists call for assistance at 1 800 858 8501 7 30 AM to 4 30 PM CST M F You may also write to HeathCo LLC ATTN Technical Service Specialty Products P O Box 90045 Bowling Green KY 42102 9045 If contacting Technical Service please have the following informat...

Page 5: ...e una superficie sólida usando dos tornillos de cabeza redonda y los orificios en la parte de atrás de la caja 3 Acomode el Detector Para una operación correcta la cabeza del detector debe girarse de modo que los controles del detector queden ubicados hacia abajo como se muestra a continuación 14 6 cm Orificios de montaje 3 Orificios de montaje 2 2008 HeathCo LLC 598 1344 00 S Características Pren...

Page 6: ...Cobertura El detector detecta movimiento por el movimiento del calor calor corporal a través del área de cobertura Sin embargo a continuación están ejemplos de objetos que pueden producir calor y hacer que el detector active una falsa alarma Charcos de agua Acondicionadores de aire Ventosas de la secadora Animales en vallas Ventosas de calefacción Tráfico automotor Si sospecha que una fuente de ca...

Page 7: ... no va a usarla por algunas semanas APAGUE la unidad Guárdela con el panel conectado y en un sitio donde el panel pueda guardar la luz solar La colección solar es solo efectiva bajo la luz directa del sol Por cada hora que la luz está prendida requiere un mínimo de 16 horas de carga de luz solar Los pa neles solares recolectan menos del 10 de la energÌa solar Si la usa durante varios días nublados...

Page 8: ...L V Usted puede también escribir a HeathCo LLC P O Box 90045 Bowling Green KY 42102 9045 ATTN Technical Service Specialty Products Servicio Técnico para Productos Especiales Si se llama al Servicio Técnico por favor tener lista la siguiente información Número de Modelo Fecha de compra y Lugar de compra No hay piezas de servicio disponibles para este producto Por favor guarde su recibo de venta fec...

Page 9: ...face solide au moyen des deux vis à tête ronde en vous servant des orifices en trou de serrure à l arrière du boîtier 3 Régler le capteur Pour fonctionner correctement le capteur doit être placé de façon que les commandes soient face au sol comme illustré ci dessous 14 6 cm Orifices de fixation 3 Orifices de fixation 2 2008 HeathCo LLC 598 1344 00 F Caractéristiques Allume l éclairage lorsqu un mo...

Page 10: ...ce de chaleur chaleur corporelle dans la zone de couverture Voici toutefois des exem ples d objets qui dégagent aussi de la chaleur et qui par conséquent peuvent entraîner le déclenchement intempestif du capteur Piscine Appareil de climatisation Évent de sécheuse Animaux en cage Évent de ventilation Circulation automobile Si vous croyez qu une source de chaleur de ce type en traîne le déclenchemen...

Page 11: ... 60 pi Varie selon la température ambiante Angle de détection Jusqu à 180 DEL 3 7 8 W Type de pile Scellée au plomb acide 6V 6 0 AH Durée de fonctionnement Essai 1 ou 5 minutes réglable Durée de fonctionnement à pleine charge Jusqu à 1 heure REMPLACEMENT DE LA PILE Celuminaireàénergiesolairecomporteunepilerechargea ble qui peut être remplacée au besoin Suivre les étapes ci après pour remplacer la ...

Page 12: ...ste composez le 1 800 858 8501 service en anglais seulement entre 7 h 30 et 16 h 30 HNC du lundi au vendredi Vous pouvez aussi écrire au HeathCo LLC P O Box 90045 Bowling Green KY 42102 9045 ATTN Technical Service Specialty Products Service technique produits de spécialité Lors d un appel au service technique veuillez avoir les renseignements suivants à portée de main numéro du modèle date d achat...