6
204031-02
TESTING
❒
Turn on the circuit breaker and light
switch.
The detector is less sensitive to motion di-
rectly towards it and more sensitive to across
motion.
Sensor
Motion
Least Sensitive
Most Sensitive
❒
Walk through the coverage area noting
where you are when the lights turn on.
❒
If you need to change the sensitivity,
temporarily remove the fixture and make
the adjustment. Too much sensitivity may
increase false triggering.
❒
Set the amount of TIME you want the light
to stay on after motion is detected. (1, 5,
or 10 minutes).
❒
Set the amount of time after dusk you want
the lights on accent level.
NOTE: Sensor has a 1
1
/
2
minute warm up pe-
riod before it will detect motion. When
first turned on, wait 1
1
/
2
minutes.
TEST 1 5 10 MIN
ON-TIME
OFF 3 6 DUSK TO
HOUR DAWN
Avoid aiming the control at:
• Objects that change temperature rapidly,
such as
heating vents and air condition-
ers. These heat sources could cause false
triggering.
• Areas where
pets or traffic may trigger
the control.
•
Nearby large, light-colored objects
reflecting light may trigger the shut-off
feature. Do not point other lights at the
sensor.
30 ft.
(9.1 m)
Maximum Range
Maximum
Coverage Angle
6 ft.
(1.8 m)
180°
Motion
❒
Switch the on-time to TEST position and
D
ual
B
rite
®
switch to the OFF position.