29
Self-Contained Spot Merchandiser
AL2
Condenser for low temperature
alarm
-67 to 302°F
-40
Pr2
-40
AU2
Condenser for high temperature
alarm
-67 to 302°F
110
Pr2
230
AH2
Differential for condenser tempera-
ture alarm recovery
1°F to 45°F
5
Pr2
5
Ad2
Condenser temperature alarm
delay
0 to 254 min, 255 = not used
15
Pr2
15
dA2
Delay of condenser temperature
alarm at start up
0.0 to 23 hr and 50'
1.3
Pr2
1.3
bLL
Compressor OFF for condenser
low temperature alarm
n(0) - Y(1)
n
Pr2
n
AC2
Compressor OFF for condenser
high temperature alarm
n(0) - Y(1)
n
Pr2
n
tbA
Alarm relay disabling
n=no; y=yes
y
Pr2
y
oA2
Fourth relay configuration
Alr=alarm;
dEF=do not select it;
Lig = light;
AUS=AUX;
onF=always ON;
Fan = do not select it;
db = neutral zone;
cP2 = second compressor;
dF2 = do not select it;
HES = night blind
Lig
Pr2
Lig
AOP
Alarm relay polarity (oA3=Alr)
oP; CL
CL
Pr2
CL
ı1P
Digital input polarity (18-20)
oP=opening; CL=closing
CL
Pr1
CL
ı1F
Digital input 1 configuration (18-20) dor; dEF
dor
Pr1
dor
ı2P
Digital input polarity (18-19)
oP=opening; CL=closing
CL
Pr2
CL
ı2F
Digital input configuration (18-19)
EAL-bAL-PAL-dor-dEF-ES-AUS-
Htr-Fan-HdF-onF
EAL
Pr2
EAL
did
Digital input alarm delay (18-20)
0 to 255 min
15
Pr1
15
doA
Door open alarm delay
0 to 255 min
15
Pr1
15
Label
Name
Range
Value
Level
Setting
nPS
Number of activation of pressure
switch
0 to 15
15
Pr2
15
Odc
Compress status when open door
no; Fan; CPr; F-C
F_C
Pr2
no
rrd
Regulation restart with door open
alarm
n-Y
y
Pr2
y
HES
Differential for Energy Saving
-54°F to 54°F
0
Pr2
0
Hur*
Current hour
0 to 23
-
Pr1
-
Min*
Current minute
0 to 59
-
Pr1
-
dAY*
Current day
Sun to SAt
-
Pr1
-
Hd1*
First weekly holiday
Sun to SAt - not used
not used
Pr1
not used
Hd2*
Second weekly holiday
Sun to SAt - not used
not used
Pr1
not used
ILE*
Energy Saving cycle start during
workdays
0 to 23hr 50 min
0.0
Pr1
0.0
dLE*
Energy Saving cycle length during
workdays
0 to 24hr 00 min
0
Pr1
0