Heat & Glo • FB-ZC • 2019-900 Rev. F • 1/07
11
A. Venting Components
7
7
Installing Vent Pipe and Appliance
The vertical vent termination system installed on this model
includes:
• One 3-foot section stainless steel
À
exible pipe (included
with insert).
• One length of 3-inch
À
exible vent pipe for combustion air
(included with vent kit).
• Flexible vent pipe for exhaust air (included with vent kit).
• One pipe-to-cap adaptor (included with vent kit).
• One vertical termination cap (included with vent kit).
B. Connecting Vent Pipe
Reference instructions in the termination kit.
• Install the 3-inch
À
exible vent pipe(s) down through the
chimney.
• Secure the exhaust
À
exible vent pipe to the 3 foot section
stainless steel flexible vent pipe using the factory-
installed 3-inch collar in the stainless steel section of
pipe (see Figure 7.1).
• Use 3 screws to attach either a 4 foot or 30 foot section
of inlet air vent to the inlet collar on the collar slide plate
(see Figure 7.1). NOTE: The collar slide plate may be
removed from appliance to aid installation.
• Seal opening between
À
ex vent and chimney just above
insert. Unfaced
¿
berglass insulation may be used for this
purpose.
CAUTION
Sharp Edges
• Wear protective gloves and safety
glasses during installation.